This work describes the three-dimensional survey of “Ex Stazione Frigorifera Specializzata”: initially used for agricultural storage, during the years it was allocated to different uses until the complete neglect. The historical relevance and the architectural heritage that this building represents has brought the start of a recent renovation project and functional restoration. In this regard it was necessary a global 3-D survey that was based on the application and integration of different geomatic methodologies (mainly terrestrial laser scanner, classical topography, and GNSS). The acquisitions of point clouds was performed using different laser scanners: with time of flight (TOF) and phase shift technologies for the distance measurements. The topographic reference network, needed for scans alignment in the same system, was measured with a total station. For the complete survey of the building, 122 scans were acquired and 346 targets were measured from 79 vertices of the reference network. Moreover, 3 vertices were measured with GNSS methodology in order to georeference the network. For the detail survey of machine room were executed 14 scans with 23 targets. The 3-D global model of the building have less than one centimeter of error in the alignment (for the machine room the error in alignment is not greater than 6 mm) and was used to extract products such as longitudinal and transversal sections, plans, architectural perspectives, virtual scans. A complete spatial knowledge of the building is obtained from the processed data, providing basic information for restoration project, structural analysis, industrial and architectural heritage valorization.

3-D survey applied to industrial archaeology by TLS methodology

Monego, Michele;FABRIS, MASSIMO;MENIN, ANDREA;ACHILLI, VLADIMIRO
2017

Abstract

This work describes the three-dimensional survey of “Ex Stazione Frigorifera Specializzata”: initially used for agricultural storage, during the years it was allocated to different uses until the complete neglect. The historical relevance and the architectural heritage that this building represents has brought the start of a recent renovation project and functional restoration. In this regard it was necessary a global 3-D survey that was based on the application and integration of different geomatic methodologies (mainly terrestrial laser scanner, classical topography, and GNSS). The acquisitions of point clouds was performed using different laser scanners: with time of flight (TOF) and phase shift technologies for the distance measurements. The topographic reference network, needed for scans alignment in the same system, was measured with a total station. For the complete survey of the building, 122 scans were acquired and 346 targets were measured from 79 vertices of the reference network. Moreover, 3 vertices were measured with GNSS methodology in order to georeference the network. For the detail survey of machine room were executed 14 scans with 23 targets. The 3-D global model of the building have less than one centimeter of error in the alignment (for the machine room the error in alignment is not greater than 6 mm) and was used to extract products such as longitudinal and transversal sections, plans, architectural perspectives, virtual scans. A complete spatial knowledge of the building is obtained from the processed data, providing basic information for restoration project, structural analysis, industrial and architectural heritage valorization.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3235701
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact