The Absorb biovascular scaffold (BVS) is a bioresorbable, everolimus-eluting scaffold whose data on real-world patients with complex lesions are limited. Short-term follow-up from recent studies point to a higher rate of 30-day thrombosis than observed with drug-eluting stents. We aimed to understand the short-term safety and efficacy of BVS. Registro Absorb Italiano (RAI, ClinicalTrials.gov:NCT02298413) is an Italian, prospective, multicenter registry not funded, whose aim is to investigate BVS performance through a 5-year follow-up of all consecutive patients who have undergone successful implantation of ≥1 BVS in different clinical/lesion subsets. Co-primary end points were target lesion revascularization and definite/probable thrombosis. Secondary end point was the occurrence of device-oriented cardiac events. The registry involved 23 centers, with patient enrollment from October 2012 to December 2015. We here report the 30-day outcomes of the whole population of the registry. We enrolled 1,505 consecutive patients, of which 82% were men and 22.4% diabetic. At presentation, 59.6% of the patients had an acute coronary syndrome, including 21% ST-elevation myocardial infarction. All lesions were pre-dilated and in 96.8% of the cases BVS was post-dilated. At 30 days, the co-primary study end point target lesion revascularization occurred in 0.6% of patients and definite/probable BVS thrombosis in 0.8%. There were 2 cases of cardiac and overall death (0.13%). Device-oriented cardiac events occurred in 1% of the patients. In conclusion, our data of consecutive patients suggest that current use of BVS in a wide spectrum of coronary narrowings and clinical settings is associated with good outcome at 30 days.

Thirty-Day Outcomes After Unrestricted Implantation of Bioresorbable Vascular Scaffold (from the Prospective RAI Registry)

Tarantini, Giuseppe;
2017

Abstract

The Absorb biovascular scaffold (BVS) is a bioresorbable, everolimus-eluting scaffold whose data on real-world patients with complex lesions are limited. Short-term follow-up from recent studies point to a higher rate of 30-day thrombosis than observed with drug-eluting stents. We aimed to understand the short-term safety and efficacy of BVS. Registro Absorb Italiano (RAI, ClinicalTrials.gov:NCT02298413) is an Italian, prospective, multicenter registry not funded, whose aim is to investigate BVS performance through a 5-year follow-up of all consecutive patients who have undergone successful implantation of ≥1 BVS in different clinical/lesion subsets. Co-primary end points were target lesion revascularization and definite/probable thrombosis. Secondary end point was the occurrence of device-oriented cardiac events. The registry involved 23 centers, with patient enrollment from October 2012 to December 2015. We here report the 30-day outcomes of the whole population of the registry. We enrolled 1,505 consecutive patients, of which 82% were men and 22.4% diabetic. At presentation, 59.6% of the patients had an acute coronary syndrome, including 21% ST-elevation myocardial infarction. All lesions were pre-dilated and in 96.8% of the cases BVS was post-dilated. At 30 days, the co-primary study end point target lesion revascularization occurred in 0.6% of patients and definite/probable BVS thrombosis in 0.8%. There were 2 cases of cardiac and overall death (0.13%). Device-oriented cardiac events occurred in 1% of the patients. In conclusion, our data of consecutive patients suggest that current use of BVS in a wide spectrum of coronary narrowings and clinical settings is associated with good outcome at 30 days.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3243417
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact