Purpose To assess the diagnostic accuracy of iXip, a novel biomarker for prostate cancer detection at initial biopsy based on an algorithm including patient age, prostate volume, PSA and PSA-IgM levels,. Materials and methods This was a prospective multicenter study involving 426 consecutive men undergoing initial prostate biopsy with at least 12 cores in a real-life clinical setting. Diagnostic accuracy of iXip for prostate cancer detection was calculated with AUC and compared to that of prostate volume, PSA and PSA-IgM levels. The correlation of iXip with tumor aggressiveness, defined as any cancer with Gleason score ≥7, was evaluated by Spearman ρ coefficient analysis. Results Prostate cancer was diagnosed in 193/426 patients (45%), of which 65 (35%) had Gleason score ≥7. iXip values were significantly higher in patients with cancer than in those without cancer (median value 55% vs. 39%, p<0.001). iXip was the most accurate predictor of cancer (AUC=0.711), followed by prostate volume (AUC=0.660) and PSA level (AUC=0.543). By setting iXip cut-off at 20%, no patients with iXip values below the cut-off were diagnosed with cancer, resulting in a 5.6% (24/426) reduction of unnecessary prostate biopsies. A significant correlation between iXip values and Gleason score was observed (ρ=0.347; p<0.001). Conclusions Our prospective multicenter study suggests that the novel biomarker iXip may be used with a 20% cut-off value in order to reduce the proportion of prostate biopsies by approximately 5%, without missing a single case of cancer. Moreover, higher iXip values are significantly correlated with tumor aggressiveness. © 2017 Elsevier Ltd

Clinical validation of the iXip index in avoiding unnecessary prostate biopsy: Results from a prospective multicenter study involving 426 patients

Plebani, Mario;Zattoni, Filiberto
2017

Abstract

Purpose To assess the diagnostic accuracy of iXip, a novel biomarker for prostate cancer detection at initial biopsy based on an algorithm including patient age, prostate volume, PSA and PSA-IgM levels,. Materials and methods This was a prospective multicenter study involving 426 consecutive men undergoing initial prostate biopsy with at least 12 cores in a real-life clinical setting. Diagnostic accuracy of iXip for prostate cancer detection was calculated with AUC and compared to that of prostate volume, PSA and PSA-IgM levels. The correlation of iXip with tumor aggressiveness, defined as any cancer with Gleason score ≥7, was evaluated by Spearman ρ coefficient analysis. Results Prostate cancer was diagnosed in 193/426 patients (45%), of which 65 (35%) had Gleason score ≥7. iXip values were significantly higher in patients with cancer than in those without cancer (median value 55% vs. 39%, p<0.001). iXip was the most accurate predictor of cancer (AUC=0.711), followed by prostate volume (AUC=0.660) and PSA level (AUC=0.543). By setting iXip cut-off at 20%, no patients with iXip values below the cut-off were diagnosed with cancer, resulting in a 5.6% (24/426) reduction of unnecessary prostate biopsies. A significant correlation between iXip values and Gleason score was observed (ρ=0.347; p<0.001). Conclusions Our prospective multicenter study suggests that the novel biomarker iXip may be used with a 20% cut-off value in order to reduce the proportion of prostate biopsies by approximately 5%, without missing a single case of cancer. Moreover, higher iXip values are significantly correlated with tumor aggressiveness. © 2017 Elsevier Ltd
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3255277
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? ND
social impact