This study investigates, both experimentally and numerically, the radiation shielding properties of two types of heavyweight concretes, one containing barite and one made with Electric Arc Furnace (EAF) slag as coarse aggregates. Fresh and hardened concrete properties are preliminary analyzed and compared to a conventional mix containing natural aggregates, namely: fresh and hard bulk density, consistency, compressive and tensile strength, elastic modulus. Three specimens per each mix are subsequently irradiated with both a high-activity (8.97TBq) and a low-activity (280kBq) 60Co gamma-ray source to measure their linear attenuation coefficients. Gamma-ray shielding characteristics are also numerically analyzed via a Monte Carlo code assessing radiation transport calculations. Experimental and numerical results indicate that EAF concrete has comparable shielding properties to baritic one, and it allows a certain decrease in thickness of the radiation shield, if compared to an ordinary concrete, however it has superior mechanical properties than the other studied mixtures

Gamma-ray shielding properties of heavyweight concrete with Electric Arc Furnace slag as aggregate: An experimental and numerical study

Pomaro, Beatrice;Gramegna, Fabiana;Salomoni, Valentina
;
Faleschini, Flora
2019

Abstract

This study investigates, both experimentally and numerically, the radiation shielding properties of two types of heavyweight concretes, one containing barite and one made with Electric Arc Furnace (EAF) slag as coarse aggregates. Fresh and hardened concrete properties are preliminary analyzed and compared to a conventional mix containing natural aggregates, namely: fresh and hard bulk density, consistency, compressive and tensile strength, elastic modulus. Three specimens per each mix are subsequently irradiated with both a high-activity (8.97TBq) and a low-activity (280kBq) 60Co gamma-ray source to measure their linear attenuation coefficients. Gamma-ray shielding characteristics are also numerically analyzed via a Monte Carlo code assessing radiation transport calculations. Experimental and numerical results indicate that EAF concrete has comparable shielding properties to baritic one, and it allows a certain decrease in thickness of the radiation shield, if compared to an ordinary concrete, however it has superior mechanical properties than the other studied mixtures
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3287009
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 69
  • ???jsp.display-item.citation.isi??? 59
social impact