Digital slides created by whole-slide imaging scanners can be evaluated by pathologists located in remote sites, but the process must be validated before this technology can be applied to routine cytological diagnosis. The aim of this study was to validate a whole-slide imaging scanner for cytological samples. Sixty cytological samples, whose diagnoses were confirmed by gold-standard examinations (histology or flow cytometry), were digitalized using a whole-slide imaging scanner. Digital slides and glass slides were examined by 3 observers with different levels of cytopathological expertise. No significant differences were noted between digital and glass slides in regard to the number of cases correctly diagnosed, or the sensitivity, specificity, or diagnostic accuracy, irrespective of the observers’ expertise. The agreements between the digital slides and the gold-standard examinations were moderate to substantial, while the agreements between the glass slides and the gold-standard examinations were substantial for all 3 observers. The intraobserver agreements between digital and glass slides were substantial to almost perfect. The interobserver agreements when evaluating digital slides were moderate between observers 1 and 2 and between observers 1 and 3 while they were substantial between observers 2 and 3. In conclusion, our study demonstrated that the digital slides produced by the whole-slide imaging scanner are adequate to diagnose cytological samples and are similar among clinical pathologists with differing levels of expertise.

Diagnostic Validation of a Whole-Slide Imaging Scanner in Cytological Samples: Diagnostic Accuracy and Comparison With Light Microscopy

Bonsembiante, Federico
Writing – Original Draft Preparation
;
Cavicchioli, Laura
Investigation
;
Gelain, Maria Elena
Conceptualization
2019

Abstract

Digital slides created by whole-slide imaging scanners can be evaluated by pathologists located in remote sites, but the process must be validated before this technology can be applied to routine cytological diagnosis. The aim of this study was to validate a whole-slide imaging scanner for cytological samples. Sixty cytological samples, whose diagnoses were confirmed by gold-standard examinations (histology or flow cytometry), were digitalized using a whole-slide imaging scanner. Digital slides and glass slides were examined by 3 observers with different levels of cytopathological expertise. No significant differences were noted between digital and glass slides in regard to the number of cases correctly diagnosed, or the sensitivity, specificity, or diagnostic accuracy, irrespective of the observers’ expertise. The agreements between the digital slides and the gold-standard examinations were moderate to substantial, while the agreements between the glass slides and the gold-standard examinations were substantial for all 3 observers. The intraobserver agreements between digital and glass slides were substantial to almost perfect. The interobserver agreements when evaluating digital slides were moderate between observers 1 and 2 and between observers 1 and 3 while they were substantial between observers 2 and 3. In conclusion, our study demonstrated that the digital slides produced by the whole-slide imaging scanner are adequate to diagnose cytological samples and are similar among clinical pathologists with differing levels of expertise.
2019
File in questo prodotto:
File Dimensione Formato  
0300985818825128.pdf

Accesso riservato

Tipologia: Published (Publisher's Version of Record)
Licenza: Accesso privato - non pubblico
Dimensione 164.4 kB
Formato Adobe PDF
164.4 kB Adobe PDF Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3287203
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 13
  • OpenAlex 16
social impact