Surface topographies of metal additively manufactured components are inherently characterized by the presence of complex surface characteristics that are not accessible by contact or optical measuring techniques. Micro X-ray computed tomography is capable of measuring non-accessible surfaces and micro-scale surface features, including undercuts. In this work, an innovative approach for evaluating the accuracy and establishing the traceability of surface topography measurements obtained by X-ray computed tomography is presented. Reference samples produced by selective laser melting of Ti6Al4V were specifically designed in order to acquire reference cross-sectional surface profiles representing the actual morphology (including re-entrant features) using an imaging probing system. Surface topographies were measured on these samples by using three different techniques: X-ray computed tomography, confocal microscopy and focus variation. Moreover, the effect of different voxel dimensions on the accuracy of surface topography measurements performed by X-ray computed tomography was investigated. Results showed that X-ray computed tomography (at the highest tested resolution) can acquire surfaces and re-entrant features with small deviations with respect to the reference profiles; the deviations were quantified. On the contrary, focus variation and confocal microscopy can measure surfaces obtaining results that are close to the reference profiles only if such surfaces have no undercuts or inaccessible features.

New Approach for Verifying the Accuracy of X-ray Computed Tomography Measurements of Surface Topographies in Additively Manufactured Metal Parts

Zanini, Filippo
;
Sbettega, Elia;Sorgato, Marco;Carmignato, Simone
2019

Abstract

Surface topographies of metal additively manufactured components are inherently characterized by the presence of complex surface characteristics that are not accessible by contact or optical measuring techniques. Micro X-ray computed tomography is capable of measuring non-accessible surfaces and micro-scale surface features, including undercuts. In this work, an innovative approach for evaluating the accuracy and establishing the traceability of surface topography measurements obtained by X-ray computed tomography is presented. Reference samples produced by selective laser melting of Ti6Al4V were specifically designed in order to acquire reference cross-sectional surface profiles representing the actual morphology (including re-entrant features) using an imaging probing system. Surface topographies were measured on these samples by using three different techniques: X-ray computed tomography, confocal microscopy and focus variation. Moreover, the effect of different voxel dimensions on the accuracy of surface topography measurements performed by X-ray computed tomography was investigated. Results showed that X-ray computed tomography (at the highest tested resolution) can acquire surfaces and re-entrant features with small deviations with respect to the reference profiles; the deviations were quantified. On the contrary, focus variation and confocal microscopy can measure surfaces obtaining results that are close to the reference profiles only if such surfaces have no undercuts or inaccessible features.
File in questo prodotto:
File Dimensione Formato  
Zanini2018_Article_NewApproachForVerifyingTheAccu.pdf

non disponibili

Descrizione: Articolo principale
Tipologia: Published (publisher's version)
Licenza: Accesso privato - non pubblico
Dimensione 2.9 MB
Formato Adobe PDF
2.9 MB Adobe PDF Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3299733
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 19
  • OpenAlex ND
social impact