Background and objectives: Transthoracic echocardiography may potentially be useful to obtain a prompt, accurate and non-invasive estimation of cardiac output. We evaluated whether non-cardiologist intensivists may obtain accurate and reproducible cardiac output determination in hemodynamically unstable mechanically ventilated patients. Methods: We studied 25 hemodynamically unstable mechanically ventilated intensive care unit patients with a pulmonary artery catheter in place. Cardiac output was calculated using the pulsed Doppler transthoracic echocardiography technique applied to the left ventricular outflow tract in apical 5 chamber view by two intensive care unit physicians who had received a basic Transthoracic Echocardiography training plus a specific training focused on Doppler, left ventricular outflow tract and velocity-time integral determination. Results: Cardiac output assessment by transthoracic echocardiography was feasible in 20 out of 25 enrolled patients (80%) and showed an excellent inter-operator reproducibility (Pearson correlation test r= 0.987; Cohen's K=0.840). Overall, the mean bias was 0.03 L.min(-1), with limits of agreement -0.52 and +0.57 L.min(-1). The concordance correlation coefficient (rho(c)) was 0.986 (95% IC 0.966-0.995) and 0.995 (95% IC 0.986-0.998) for physician 1 and 2, respectively. The value of accuracy (C-b) of COTTE measurement was 0.999 for both observers. The value of precision (rho) of CO (TEE) measurement was 0.986 and 0.995 for observer 1 and 2, respectively. Conclusions: A specific training focused on Doppler and VTI determination added to the standard basic transthoracic echocardiography training allowed non-cardiologist intensive care unit physicians to achieve a quick, reproducible and accurate snapshot cardiac output assessment in the majority of mechanically ventilated intensive care unit patients. (C) 2018 Sociedade Brasileira de Anestesiologia.

Transthoracic echocardiographic assessment of cardiac output in mechanically ventilated critically ill patients by intensive care unit physicians

Navalesi P
2019

Abstract

Background and objectives: Transthoracic echocardiography may potentially be useful to obtain a prompt, accurate and non-invasive estimation of cardiac output. We evaluated whether non-cardiologist intensivists may obtain accurate and reproducible cardiac output determination in hemodynamically unstable mechanically ventilated patients. Methods: We studied 25 hemodynamically unstable mechanically ventilated intensive care unit patients with a pulmonary artery catheter in place. Cardiac output was calculated using the pulsed Doppler transthoracic echocardiography technique applied to the left ventricular outflow tract in apical 5 chamber view by two intensive care unit physicians who had received a basic Transthoracic Echocardiography training plus a specific training focused on Doppler, left ventricular outflow tract and velocity-time integral determination. Results: Cardiac output assessment by transthoracic echocardiography was feasible in 20 out of 25 enrolled patients (80%) and showed an excellent inter-operator reproducibility (Pearson correlation test r= 0.987; Cohen's K=0.840). Overall, the mean bias was 0.03 L.min(-1), with limits of agreement -0.52 and +0.57 L.min(-1). The concordance correlation coefficient (rho(c)) was 0.986 (95% IC 0.966-0.995) and 0.995 (95% IC 0.986-0.998) for physician 1 and 2, respectively. The value of accuracy (C-b) of COTTE measurement was 0.999 for both observers. The value of precision (rho) of CO (TEE) measurement was 0.986 and 0.995 for observer 1 and 2, respectively. Conclusions: A specific training focused on Doppler and VTI determination added to the standard basic transthoracic echocardiography training allowed non-cardiologist intensive care unit physicians to achieve a quick, reproducible and accurate snapshot cardiac output assessment in the majority of mechanically ventilated intensive care unit patients. (C) 2018 Sociedade Brasileira de Anestesiologia.
File in questo prodotto:
File Dimensione Formato  
Bergamaschi Transthoracic echocardiographic assessment of cardiac output in mechanically ventilated critically ill patients by intensive care unit physicians.pdf

accesso aperto

Tipologia: Published (publisher's version)
Licenza: Creative commons
Dimensione 683.03 kB
Formato Adobe PDF
683.03 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3312333
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 4
social impact