The aim of this study was to assess whether the in vivo specific force and architectural characteristics of the lateral gastrocnemius (GL) muscle of early pubescent boys (n = 11, age = 10.9 ± 0.3 yr, Tanner stage 2) differed from those of adult men (n = 12, age = 25.3 ± 4.4 yr). Plantarflexor torque was 55% lower in the boys (77.4 ± 21.4 N·m) compared with the adults (175.6 ± 31.7 N·m, P < 0.01). Physiological cross-sectional area (PCSA), determined in vivo using ultrasonography and MRI, was 52% smaller in the boys (P < 0.01). No difference was found in pennation angle, or in the ratio of fascicle length (Lf) to muscle length between the boys and men. Moment arm length was 25% smaller in the boys (P < 0.01). Antagonist coactivation, assessed using surface EMG on the dorsiflexors, was not different between the boys and men (11.8 ± 6.7% and 13.5 ± 5.8%, respectively). Surprisingly, GL force normalized to PCSA (specific force) was significantly higher (21%) in the boys than in the men (13.1 ± 2.0 vs. 15.9 ± 2.7 N/cm2, P < 0.05). This finding could not be explained by differences in moment arm length, muscle activation, or architecture, and other factors, such as tendinous characteristics and/or changes in moment arm length with contraction, may be held responsible. These observations warrant further investigation. Copyright © 2008 the American Physiological Society.

Gastrocnemius muscle specific force in boys and men

Narici, M. V.
2008

Abstract

The aim of this study was to assess whether the in vivo specific force and architectural characteristics of the lateral gastrocnemius (GL) muscle of early pubescent boys (n = 11, age = 10.9 ± 0.3 yr, Tanner stage 2) differed from those of adult men (n = 12, age = 25.3 ± 4.4 yr). Plantarflexor torque was 55% lower in the boys (77.4 ± 21.4 N·m) compared with the adults (175.6 ± 31.7 N·m, P < 0.01). Physiological cross-sectional area (PCSA), determined in vivo using ultrasonography and MRI, was 52% smaller in the boys (P < 0.01). No difference was found in pennation angle, or in the ratio of fascicle length (Lf) to muscle length between the boys and men. Moment arm length was 25% smaller in the boys (P < 0.01). Antagonist coactivation, assessed using surface EMG on the dorsiflexors, was not different between the boys and men (11.8 ± 6.7% and 13.5 ± 5.8%, respectively). Surprisingly, GL force normalized to PCSA (specific force) was significantly higher (21%) in the boys than in the men (13.1 ± 2.0 vs. 15.9 ± 2.7 N/cm2, P < 0.05). This finding could not be explained by differences in moment arm length, muscle activation, or architecture, and other factors, such as tendinous characteristics and/or changes in moment arm length with contraction, may be held responsible. These observations warrant further investigation. Copyright © 2008 the American Physiological Society.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3321756
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 73
  • ???jsp.display-item.citation.isi??? 66
  • OpenAlex 81
social impact