In the frame of space missions, mechanisms often constitute critical systems whose functionality and performance need to be tested on ground before the mission launch. The LISA scientific space mission will detect gravitational waves by measuring the relative displacement of pairs of free-floating test masses set into geodesic motion onboard of three spacecrafts. Inside each satellite, the injection of the test masses from the caged configuration into the geodesic trajectory will be performed by the grabbing positioning and release mechanism. To provide a successful injection, the test masses must be dynamically released with a minimal residual velocity against adhesion with the holding device. A parameter that determines the test mass residual velocity is the quickness of the retraction of the holding device. The need arises then to characterize the dynamic response of the release mechanism in order to predict its behaviour in the in-flight conditions. Once a validated model of the mechanism is available, the compliance of the system to the tight requirement on the maximum allowed residual velocity of the test mass may be verified. Starting from an electro-mechanical model of the mechanism dynamics, this paper presents the results of the experimental identification of its relevant parameters. © 2010 COSPAR. Published by Elsevier Ltd. All rights reserved.

Modeling and identification of an electro-mechanical system: The LISA grabbing positioning and release mechanism case

Antonello Riccardo;
2011

Abstract

In the frame of space missions, mechanisms often constitute critical systems whose functionality and performance need to be tested on ground before the mission launch. The LISA scientific space mission will detect gravitational waves by measuring the relative displacement of pairs of free-floating test masses set into geodesic motion onboard of three spacecrafts. Inside each satellite, the injection of the test masses from the caged configuration into the geodesic trajectory will be performed by the grabbing positioning and release mechanism. To provide a successful injection, the test masses must be dynamically released with a minimal residual velocity against adhesion with the holding device. A parameter that determines the test mass residual velocity is the quickness of the retraction of the holding device. The need arises then to characterize the dynamic response of the release mechanism in order to predict its behaviour in the in-flight conditions. Once a validated model of the mechanism is available, the compliance of the system to the tight requirement on the maximum allowed residual velocity of the test mass may be verified. Starting from an electro-mechanical model of the mechanism dynamics, this paper presents the results of the experimental identification of its relevant parameters. © 2010 COSPAR. Published by Elsevier Ltd. All rights reserved.
2011
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0273117710006058-main.pdf

Accesso riservato

Descrizione: Articolo principale
Tipologia: Published (Publisher's Version of Record)
Licenza: Accesso privato - non pubblico
Dimensione 1.47 MB
Formato Adobe PDF
1.47 MB Adobe PDF Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3330944
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 28
  • OpenAlex ND
social impact