Purpose: The Italian Tailored Assessment of Lung Indeterminate Accidental Nodule (ITAL-IAN) trial is a trial drawn to determine the performance of 18F-FDG-PET/CT in patients with solitary pulmonary nodules (SPN), stratified for a different kind of risk. An additional end-point was to com-pare the diagnostic information and estimated dosimetry, provided by a segmental PET/CT (s-PET/CT) acquisition instead of a whole body PET/CT (wb-PET/CT), in order to evaluate if segmental thoracic PET/CT can be used in patients with SPN. Methods: 18F-FDG PET/CT of 502 patients, stratified for pre-test cancer risk, was retrospectively analyzed. FDG uptake in SPN was assessed by a 4-point scoring (4PS) system and a semiquantitative analysis using the ratio between SUVmax in SPN and SUVmean in mediastinal blood pool (BP), and between SUVmax in SPN and SUVmean in the liver (L). Histopathology and/or follow-up data were used as a standard of reference. Data obtained on the thoracic part of wb-PET/CT, defin...

The multicenter ITALIAN trial assess the performance of FDG-PET/CT related to pre-test cancer risk in patients with solitary pulmonary nodules and introduces a segmental thoracic diagnostic strategy

Evangelista, Laura;
2020

Abstract

Purpose: The Italian Tailored Assessment of Lung Indeterminate Accidental Nodule (ITAL-IAN) trial is a trial drawn to determine the performance of 18F-FDG-PET/CT in patients with solitary pulmonary nodules (SPN), stratified for a different kind of risk. An additional end-point was to com-pare the diagnostic information and estimated dosimetry, provided by a segmental PET/CT (s-PET/CT) acquisition instead of a whole body PET/CT (wb-PET/CT), in order to evaluate if segmental thoracic PET/CT can be used in patients with SPN. Methods: 18F-FDG PET/CT of 502 patients, stratified for pre-test cancer risk, was retrospectively analyzed. FDG uptake in SPN was assessed by a 4-point scoring (4PS) system and a semiquantitative analysis using the ratio between SUVmax in SPN and SUVmean in mediastinal blood pool (BP), and between SUVmax in SPN and SUVmean in the liver (L). Histopathology and/or follow-up data were used as a standard of reference. Data obtained on the thoracic part of wb-PET/CT, defin...
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3341687
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
  • OpenAlex ND
social impact