Purpose: To evaluate patient perception and operating time of digital (DW) and conventional (CW) workflows for the rehabilitation of a screw-retained, single-implant crown. Materials and Methods: A convenience sample of 10 patients with single implants in posterior sites was recruited for treatment with screw-retained single crowns, fabricated with either a DW or a CW protocol. Operating time and clinical adjusting time were recorded with a stopwatch, and patient preference and self-perception of the esthetic outcome were evaluated with a visual analog scale. Results: The mean operating time for the DW crowns was 16:21 minutes and for the CW crowns was 28:28 minutes. The mean total adjustment times were 118.1 seconds for the DW protocol and 181.5 seconds for the CW protocol. The mean score regarding self-perception of the esthetic outcome was 73 for DW crowns and 69 for CW crowns; for discomfort, the mean score was 15.5 for DW and 62 for CW. Conclusion: The DW approach resulted in a time reduction for both the impression phase and operative time.

Digital vs conventional workflow for screw-retained single-implant crowns: A comparison of key considerations

Di Fiore A.
;
Vigolo P.;Graiff L.;Stellini E.
2018

Abstract

Purpose: To evaluate patient perception and operating time of digital (DW) and conventional (CW) workflows for the rehabilitation of a screw-retained, single-implant crown. Materials and Methods: A convenience sample of 10 patients with single implants in posterior sites was recruited for treatment with screw-retained single crowns, fabricated with either a DW or a CW protocol. Operating time and clinical adjusting time were recorded with a stopwatch, and patient preference and self-perception of the esthetic outcome were evaluated with a visual analog scale. Results: The mean operating time for the DW crowns was 16:21 minutes and for the CW crowns was 28:28 minutes. The mean total adjustment times were 118.1 seconds for the DW protocol and 181.5 seconds for the CW protocol. The mean score regarding self-perception of the esthetic outcome was 73 for DW crowns and 69 for CW crowns; for discomfort, the mean score was 15.5 for DW and 62 for CW. Conclusion: The DW approach resulted in a time reduction for both the impression phase and operative time.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3353946
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 37
social impact