PURPOSE: Reconstructing the occlusal morphology of posterior teeth in definitive dental prosthesis can be challenging.The use of the correlation technique enables replication of the information and occlusal anatomy of interim dental prostheses to the definitive ones. The purpose of this controlled clinical trial was to compare the static and dynamic contacts (SDC) of monolithic zirconia crowns designed with correlation and library techniques.MATERIAL AND METHODS: Twenty-four patients were included in the study for a total of 28molars. For each abutment tooth, an interim crown was fabricated and two digital scans, with and without the interim crown in place were made. Two single crowns were designed using correlation and library techniques. Fifty-six monolithic zirconia crowns were milled. The interim and definitive crowns were evaluated intraorally for SDC by using a 24 mum-thick blue articulating foil. After removing the interim and definite crowns, extraoral photographs were taken to calculate the SDC area using software (ImageJ) and analyzed by the Kruskal-Wallis test.RESULTS: The average and ± standard deviation (SD) of area of the occlusal marks on interim crowns was 32.27 ±3.45 mm2 . Definitive crowns designed by using the correlation technique had an area of 31.01 ±3.73 mm2 ; the area in the library technique was 36.85 ±5.78 mm2 . No statistically significant difference was found (P=0.091) between the occlusal mark areas of the interim and definitive crowns designed by using the correlation technique. Whereas, there were significant differences between the areas of occlusal marks of the interim anddefinitive crowns designed by using the library technique, and between the areas of occlusal marks of definitive crowns designed by using the correlation and library techniques (P<0.001).CONCLUSION: The average area of the SDC of monolithic zirconia crowns designed by using the correlation technique was similar to that of interim crowns. The library technique was less effective when replicating the SDC compared to the correlation technique. This article is protected by copyright. All rights reserved.

Automatic Digital Design of the Occlusal Anatomy of Monolithic Zirconia Crowns Compared to Dental Technicians' Digital Waxing: A Controlled Clinical Trial

Fiore, Adolfo Di
;
Monaco, Carlo;Brunello, Giulia;Stellini, Edoardo;
2020

Abstract

PURPOSE: Reconstructing the occlusal morphology of posterior teeth in definitive dental prosthesis can be challenging.The use of the correlation technique enables replication of the information and occlusal anatomy of interim dental prostheses to the definitive ones. The purpose of this controlled clinical trial was to compare the static and dynamic contacts (SDC) of monolithic zirconia crowns designed with correlation and library techniques.MATERIAL AND METHODS: Twenty-four patients were included in the study for a total of 28molars. For each abutment tooth, an interim crown was fabricated and two digital scans, with and without the interim crown in place were made. Two single crowns were designed using correlation and library techniques. Fifty-six monolithic zirconia crowns were milled. The interim and definitive crowns were evaluated intraorally for SDC by using a 24 mum-thick blue articulating foil. After removing the interim and definite crowns, extraoral photographs were taken to calculate the SDC area using software (ImageJ) and analyzed by the Kruskal-Wallis test.RESULTS: The average and ± standard deviation (SD) of area of the occlusal marks on interim crowns was 32.27 ±3.45 mm2 . Definitive crowns designed by using the correlation technique had an area of 31.01 ±3.73 mm2 ; the area in the library technique was 36.85 ±5.78 mm2 . No statistically significant difference was found (P=0.091) between the occlusal mark areas of the interim and definitive crowns designed by using the correlation technique. Whereas, there were significant differences between the areas of occlusal marks of the interim anddefinitive crowns designed by using the library technique, and between the areas of occlusal marks of definitive crowns designed by using the correlation and library techniques (P<0.001).CONCLUSION: The average area of the SDC of monolithic zirconia crowns designed by using the correlation technique was similar to that of interim crowns. The library technique was less effective when replicating the SDC compared to the correlation technique. This article is protected by copyright. All rights reserved.
2020
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3353949
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact