A module of a wireless high voltage generator was tested immersed in both gaseous and liquid environments providing electrical insulation. The overall performance of the module as well as a detailed performance of the key components are reported, and a comparison between the results in gas and liquid is given. The tests performed on the liquid dielectric show that it is a valid alternative to high pressure gas electrical insulation.
Comparison of the performance of a high voltage generator insulated by gas or liquid dielectric
Borsato E.;Carugno G.;Gobbo R.;La Torre L.;Zotto P.
2020
Abstract
A module of a wireless high voltage generator was tested immersed in both gaseous and liquid environments providing electrical insulation. The overall performance of the module as well as a detailed performance of the key components are reported, and a comparison between the results in gas and liquid is given. The tests performed on the liquid dielectric show that it is a valid alternative to high pressure gas electrical insulation.File in questo prodotto:
File | Dimensione | Formato | |
---|---|---|---|
5.0009519.pdf
accesso aperto
Descrizione: Articolo principale
Tipologia:
Published (publisher's version)
Licenza:
Accesso gratuito
Dimensione
1.24 MB
Formato
Adobe PDF
|
1.24 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate