As the population ages, an increasing number of patients with patent coronary grafts will require subsequent aortic valve replacement. Major operative problems include those associated with re-entry and, in particular, damage of the patent grafts. Between January 2007 and October 2008, 10 patients who had previous coronary bypass surgery underwent aortic valve replacement through upper j-shaped mini re-sternotomy. In all patients the previous grafts were patent. The operation was performed with normothermic cardiopulmonary bypass without dissection and temporary closure of the arterial and venous coronary bypass grafts. The mean age was 73.2±13.6 years. The patients had a mean of 2.8±0.6 bypass grafts. There were no intraoperative complications due to redo ministernotomy and at no time conversion to full re-sternotomy was necessary. No damage to the previous grafts was reported and the incidence of perioperative myocardial infarction was 0%. One patient required a pacemaker implantation for atrio-ventricular block. The in-hospital mortality was 0%. Aortic valve replacement in previous coronary bypass grafting can be performed safely with a mini re-sternotomy. This approach avoids extensive dissection, decreasing the risk of injuries to heart chambers and previous patent coronary grafts with low morbidity and mortality.

Mini re-sternotomy for aortic valve replacement in patients with patent coronary bypass grafts

Dell'Amore A.;
2009

Abstract

As the population ages, an increasing number of patients with patent coronary grafts will require subsequent aortic valve replacement. Major operative problems include those associated with re-entry and, in particular, damage of the patent grafts. Between January 2007 and October 2008, 10 patients who had previous coronary bypass surgery underwent aortic valve replacement through upper j-shaped mini re-sternotomy. In all patients the previous grafts were patent. The operation was performed with normothermic cardiopulmonary bypass without dissection and temporary closure of the arterial and venous coronary bypass grafts. The mean age was 73.2±13.6 years. The patients had a mean of 2.8±0.6 bypass grafts. There were no intraoperative complications due to redo ministernotomy and at no time conversion to full re-sternotomy was necessary. No damage to the previous grafts was reported and the incidence of perioperative myocardial infarction was 0%. One patient required a pacemaker implantation for atrio-ventricular block. The in-hospital mortality was 0%. Aortic valve replacement in previous coronary bypass grafting can be performed safely with a mini re-sternotomy. This approach avoids extensive dissection, decreasing the risk of injuries to heart chambers and previous patent coronary grafts with low morbidity and mortality.
2009
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3360377
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 8
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex 10
social impact