Scandium presents different radionuclides with good imaging and therapeutic properties for the development of theranostic radiopharmaceuticals. In particular, 47Sc (t1/2= 3.35 d) has suitable features both for SPECT imaging, thanks to the 159 keV γ-ray emission, and for treatment of small-size tumours, thanks to the intense β− emission (mean β− energy: 162.0 keV). Its efficacy has been demonstrated at preclinical stage, but its low availability has however limited the application of 47Sc-based radiopharmaceuticals to the clinic. Among the different proposed production routes, the natV(p,x)47Sc nuclear reaction is of particular interest, due to the low-cost and easy availability of the target material, as well as the widespread availability of medium-energy cyclotrons. However, the nuclear cross section of this reaction is quite low and small amounts of Sc radioactive contaminants are co-produced. The aim of this work is to evaluate the contribution of Sc-contaminants to the patient radiation dose.
Dosimetric analysis of the contribution of Radionuclides Coproduced through natV(p,x)47Sc reaction route in Cyclotron Irradiation
De Nardo L.;Rosato A.;Esposito J.;
2020
Abstract
Scandium presents different radionuclides with good imaging and therapeutic properties for the development of theranostic radiopharmaceuticals. In particular, 47Sc (t1/2= 3.35 d) has suitable features both for SPECT imaging, thanks to the 159 keV γ-ray emission, and for treatment of small-size tumours, thanks to the intense β− emission (mean β− energy: 162.0 keV). Its efficacy has been demonstrated at preclinical stage, but its low availability has however limited the application of 47Sc-based radiopharmaceuticals to the clinic. Among the different proposed production routes, the natV(p,x)47Sc nuclear reaction is of particular interest, due to the low-cost and easy availability of the target material, as well as the widespread availability of medium-energy cyclotrons. However, the nuclear cross section of this reaction is quite low and small amounts of Sc radioactive contaminants are co-produced. The aim of this work is to evaluate the contribution of Sc-contaminants to the patient radiation dose.File | Dimensione | Formato | |
---|---|---|---|
Radiation Dosimetry of Sc GICR 2020.pdf
accesso aperto
Tipologia:
Abstract
Licenza:
Accesso gratuito
Dimensione
180.41 kB
Formato
Adobe PDF
|
180.41 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.