Background: Technological progress has led to the transition to digital methods to perform surgical planning and to obtain surgical splints with CAD/CAM technologies. The present study aimed to compare the accuracy of jaw repositioning in bimaxillary orthognathic surgery using traditional and digital surgical planning in skeletal class III patients. Methods: This study included 60 skeletal class III patients divided into two groups based on the method used to perform surgical planning: traditional (T, n = 30) and digital (D, n = 30). For each patient, a 2D presurgical Visual Treatment Objective (VTO) was prepared and the outcome of the surgery was compared with that planned by using determined cephalometric measurements (ANB, SNA, SNB, Ar-Go-Me, S-Ar-Go). Statistical analysis showed that the measurements planned and those obtained after surgery were equivalent in Group D. For Group T, the analysis showed equivalence only for one of the considered measurements (ANB). By comparing the re...

The Accuracy of Jaws Repositioning in Bimaxillary Orthognathic Surgery with Traditional Surgical Planning Compared to Digital Surgical Planning in Skeletal Class III Patients: A Retrospective Observational Study

Antonio Gracco
2020

Abstract

Background: Technological progress has led to the transition to digital methods to perform surgical planning and to obtain surgical splints with CAD/CAM technologies. The present study aimed to compare the accuracy of jaw repositioning in bimaxillary orthognathic surgery using traditional and digital surgical planning in skeletal class III patients. Methods: This study included 60 skeletal class III patients divided into two groups based on the method used to perform surgical planning: traditional (T, n = 30) and digital (D, n = 30). For each patient, a 2D presurgical Visual Treatment Objective (VTO) was prepared and the outcome of the surgery was compared with that planned by using determined cephalometric measurements (ANB, SNA, SNB, Ar-Go-Me, S-Ar-Go). Statistical analysis showed that the measurements planned and those obtained after surgery were equivalent in Group D. For Group T, the analysis showed equivalence only for one of the considered measurements (ANB). By comparing the re...
2020
File in questo prodotto:
File Dimensione Formato  
jcm-09-01840-v2.pdf

accesso aperto

Tipologia: Published (Publisher's Version of Record)
Licenza: Creative commons
Dimensione 232.61 kB
Formato Adobe PDF
232.61 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3369363
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 16
  • OpenAlex 20
social impact