Background: Technological progress has led to the transition to digital methods to perform surgical planning and to obtain surgical splints with CAD/CAM technologies. The present study aimed to compare the accuracy of jaw repositioning in bimaxillary orthognathic surgery using traditional and digital surgical planning in skeletal class III patients. Methods: This study included 60 skeletal class III patients divided into two groups based on the method used to perform surgical planning: traditional (T, n = 30) and digital (D, n = 30). For each patient, a 2D presurgical Visual Treatment Objective (VTO) was prepared and the outcome of the surgery was compared with that planned by using determined cephalometric measurements (ANB, SNA, SNB, Ar-Go-Me, S-Ar-Go). Statistical analysis showed that the measurements planned and those obtained after surgery were equivalent in Group D. For Group T, the analysis showed equivalence only for one of the considered measurements (ANB). By comparing the re...
The Accuracy of Jaws Repositioning in Bimaxillary Orthognathic Surgery with Traditional Surgical Planning Compared to Digital Surgical Planning in Skeletal Class III Patients: A Retrospective Observational Study
Antonio Gracco
2020
Abstract
Background: Technological progress has led to the transition to digital methods to perform surgical planning and to obtain surgical splints with CAD/CAM technologies. The present study aimed to compare the accuracy of jaw repositioning in bimaxillary orthognathic surgery using traditional and digital surgical planning in skeletal class III patients. Methods: This study included 60 skeletal class III patients divided into two groups based on the method used to perform surgical planning: traditional (T, n = 30) and digital (D, n = 30). For each patient, a 2D presurgical Visual Treatment Objective (VTO) was prepared and the outcome of the surgery was compared with that planned by using determined cephalometric measurements (ANB, SNA, SNB, Ar-Go-Me, S-Ar-Go). Statistical analysis showed that the measurements planned and those obtained after surgery were equivalent in Group D. For Group T, the analysis showed equivalence only for one of the considered measurements (ANB). By comparing the re...File | Dimensione | Formato | |
---|---|---|---|
jcm-09-01840-v2.pdf
accesso aperto
Tipologia:
Published (Publisher's Version of Record)
Licenza:
Creative commons
Dimensione
232.61 kB
Formato
Adobe PDF
|
232.61 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.