Background: To evaluate digital tracheal intubation (DTI) when compared to laryngoscope-assisted TI; finger palpation of endotracheal tube (ETT) tip position when compared to any standard method. Design: A systematic review of Medline, Embase, CENTRAL, and CINAHL with synthesis of data using meta-analysis was performed. Main outcome measure: The proportion of successful TI and correct ETT tip positioning were the main outcome measures. Results: Five studies (one observational study and four RCTs) enrolling 310 neonates were included. 94% (81%–98%) of the DTI were successful on the first attempt (certainty of evidence [CoE]: low). The proportion of successful intubation on the first attempt was higher with DTI when compared to laryngoscope-assisted TI (RR 95% CI: 1.81 [1.18; 2.76]) (CoE: very low). Time to successful TI with DTI was 7.4 (95% CI: 6.3, 8.5) s (CoE: low). Time to successful TI was significantly shorter with DTI when compared to laryngoscope assisted TI (MD [95% CI]: −4.9 [−7.3, −2.4] s) (CoE: very low). There was a trend towards a higher proportion of correct ETT tip positions with finger palpation when compared to weight-based formulae alone (RR 95% CI: 1.12 [0.96; 1.31]) (CoE: very low). Conclusions: DTI and finger palpation to ascertain ETT tip position in neonates are promising strategies. Future studies with emphasis on their learning trajectory and generalizability are needed.

Digital tracheal intubation and finger palpation to confirm endotracheal tube tip position in neonates: A systematic review and meta-analysis

Daniele Trevisanuto
2021

Abstract

Background: To evaluate digital tracheal intubation (DTI) when compared to laryngoscope-assisted TI; finger palpation of endotracheal tube (ETT) tip position when compared to any standard method. Design: A systematic review of Medline, Embase, CENTRAL, and CINAHL with synthesis of data using meta-analysis was performed. Main outcome measure: The proportion of successful TI and correct ETT tip positioning were the main outcome measures. Results: Five studies (one observational study and four RCTs) enrolling 310 neonates were included. 94% (81%–98%) of the DTI were successful on the first attempt (certainty of evidence [CoE]: low). The proportion of successful intubation on the first attempt was higher with DTI when compared to laryngoscope-assisted TI (RR 95% CI: 1.81 [1.18; 2.76]) (CoE: very low). Time to successful TI with DTI was 7.4 (95% CI: 6.3, 8.5) s (CoE: low). Time to successful TI was significantly shorter with DTI when compared to laryngoscope assisted TI (MD [95% CI]: −4.9 [−7.3, −2.4] s) (CoE: very low). There was a trend towards a higher proportion of correct ETT tip positions with finger palpation when compared to weight-based formulae alone (RR 95% CI: 1.12 [0.96; 1.31]) (CoE: very low). Conclusions: DTI and finger palpation to ascertain ETT tip position in neonates are promising strategies. Future studies with emphasis on their learning trajectory and generalizability are needed.
2021
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3396647
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact