In this paper, a pervasive monitoring system to be deployed in underground environments is presented. The system has been specifically designed for the so-called “Bottini”, i.e., the medieval aqueducts dug beneath the Centre of Siena, Italy. The results of a measurement campaign carried out in the deployment scenario show that the transmission range of LoRa (Long Range) technology is limited to a maximum of 200 m, thus, making the adoption of a classical star topology impossible. Hence, a Linear Sensor Network topology is proposed based on multi-hop LoRa chain-type communications. In this scenario, an ad-hoc transmission scheme is presented that optimally evaluates the wake-up time of all nodes with the aim of minimizing the average energy dissipation deriving from clock offsets. Numerical results show that the proposed wake-up time optimization leads in the best case to a 50% reduction in power dissipation with respect to a scheme that evaluates the wake-up time in a non-optimal way.

A multi-hop lora linear sensor network for the monitoring of underground environments: The case of the medieval aqueducts in Siena, Italy

Pozzebon, Alessandro
2019

Abstract

In this paper, a pervasive monitoring system to be deployed in underground environments is presented. The system has been specifically designed for the so-called “Bottini”, i.e., the medieval aqueducts dug beneath the Centre of Siena, Italy. The results of a measurement campaign carried out in the deployment scenario show that the transmission range of LoRa (Long Range) technology is limited to a maximum of 200 m, thus, making the adoption of a classical star topology impossible. Hence, a Linear Sensor Network topology is proposed based on multi-hop LoRa chain-type communications. In this scenario, an ad-hoc transmission scheme is presented that optimally evaluates the wake-up time of all nodes with the aim of minimizing the average energy dissipation deriving from clock offsets. Numerical results show that the proposed wake-up time optimization leads in the best case to a 50% reduction in power dissipation with respect to a scheme that evaluates the wake-up time in a non-optimal way.
2019
File in questo prodotto:
File Dimensione Formato  
sensors-19-00402-v2.pdf

accesso aperto

Tipologia: Published (publisher's version)
Licenza: Creative commons
Dimensione 2.16 MB
Formato Adobe PDF
2.16 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3405652
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 76
  • ???jsp.display-item.citation.isi??? 60
social impact