This study aimed to determine the feasibility, reproducibility, and reliability of the multiecho T*(2) Magnetic resonance imaging technique at 3 T for myocardial and liver iron burden quantification and the relationship between T*(2) values at 3 and 1.5 T. Thirty-eight transfusion-dependent patients and 20 healthy subjects were studied. Cardiac segmental and global T*(2) values were calculated after developing a correction map to compensate the artifactual T*(2) variations. The hepatic T*(2) value was determined over a region of interest. The intraoperator and interoperator reproducibility for T*(2) measurements at 3 T was good. A linear relationship was found between patients' R *2 (1000/T*(2) ) values at 3 and 1.5 T. Segmental correction factors were significantly higher at 3 T. A conversion formula returning T*(2) values at 1.5 T from values at 3 T was proposed. A good diagnostic reliability for T*(2) assessment at 3 T was demonstrated. Lower limits of normal for 3 T T*(2) values were 23.3 ms, 21.1 ms, and 11.7 ms, for the global heart, mid-ventricular septum, and liver, respectively. In conclusion, T*(2) quantification of iron burden in the mid-ventricular septum, global heart, and no heavy-moderate livers resulted to be feasible, reproducible, and reliable at 3 T. Segmental heart T*(2) analysis at 3 T may be challenging due to significantly higher susceptibility artifacts.

Feasibility, reproducibility, and reliability for the T2* iron evaluation at 3 T in comparison with 1.5 T

Pepe A
2012

Abstract

This study aimed to determine the feasibility, reproducibility, and reliability of the multiecho T*(2) Magnetic resonance imaging technique at 3 T for myocardial and liver iron burden quantification and the relationship between T*(2) values at 3 and 1.5 T. Thirty-eight transfusion-dependent patients and 20 healthy subjects were studied. Cardiac segmental and global T*(2) values were calculated after developing a correction map to compensate the artifactual T*(2) variations. The hepatic T*(2) value was determined over a region of interest. The intraoperator and interoperator reproducibility for T*(2) measurements at 3 T was good. A linear relationship was found between patients' R *2 (1000/T*(2) ) values at 3 and 1.5 T. Segmental correction factors were significantly higher at 3 T. A conversion formula returning T*(2) values at 1.5 T from values at 3 T was proposed. A good diagnostic reliability for T*(2) assessment at 3 T was demonstrated. Lower limits of normal for 3 T T*(2) values were 23.3 ms, 21.1 ms, and 11.7 ms, for the global heart, mid-ventricular septum, and liver, respectively. In conclusion, T*(2) quantification of iron burden in the mid-ventricular septum, global heart, and no heavy-moderate livers resulted to be feasible, reproducible, and reliable at 3 T. Segmental heart T*(2) analysis at 3 T may be challenging due to significantly higher susceptibility artifacts.
2012
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3407465
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 47
social impact