INTRODUCTION: 11C-ER176 is a new PET tracer to quantify the translocator protein (TSPO), a biomarker for inflammation. The aim of this study was to perform a head-to-head comparison between 11C-ER176 and the widely used 11C-PBR28.METHODS: Seven healthy volunteers had a 90-min PET scan and metabolite-corrected arterial input function with 11C-PBR28 in the morning and 11C-ER176 in the afternoon. Binding was quantified at the regional level in terms of VT with a two-tissue compartmental model. By using VND values from the literature obtained with pharmacological blockade, we derived the binding potential BPND for both tracers.RESULTS: 11C-ER176 was more stable in arterial blood than 11C-PBR28 (the percentages of unmetabolized parent in plasma at 90 min were 29.0 ± 8.3% and 8.8 ± 2.9% respectively). The brain time-activity curves for both tracers were well fitted by the two-tissue model, but 11C-ER176 had higher VT values than 11C-PBR28 (5.74 ± 1.54 vs 4.43 ± 1.99 ml/cm3) and a lower coefficient of variation. The BPND of 11C-ER176 was more than 4 times larger than that of 11C-PBR28 for high-affinity binders, and more than 9 times larger for mixed-affinity binders.CONCLUSION: 11C-ER176 displays a higher binding potential and a smaller variability of VT values. Thanks to these characteristics, clinical studies performed with 11C-ER176 are expected to have higher statistical power and thus require fewer subjects.

Head-to-head comparison of 11C-PBR28 and 11C-ER176 for quantification of the translocator protein in the human brain

Veronese, Mattia;
2019

Abstract

INTRODUCTION: 11C-ER176 is a new PET tracer to quantify the translocator protein (TSPO), a biomarker for inflammation. The aim of this study was to perform a head-to-head comparison between 11C-ER176 and the widely used 11C-PBR28.METHODS: Seven healthy volunteers had a 90-min PET scan and metabolite-corrected arterial input function with 11C-PBR28 in the morning and 11C-ER176 in the afternoon. Binding was quantified at the regional level in terms of VT with a two-tissue compartmental model. By using VND values from the literature obtained with pharmacological blockade, we derived the binding potential BPND for both tracers.RESULTS: 11C-ER176 was more stable in arterial blood than 11C-PBR28 (the percentages of unmetabolized parent in plasma at 90 min were 29.0 ± 8.3% and 8.8 ± 2.9% respectively). The brain time-activity curves for both tracers were well fitted by the two-tissue model, but 11C-ER176 had higher VT values than 11C-PBR28 (5.74 ± 1.54 vs 4.43 ± 1.99 ml/cm3) and a lower coefficient of variation. The BPND of 11C-ER176 was more than 4 times larger than that of 11C-PBR28 for high-affinity binders, and more than 9 times larger for mixed-affinity binders.CONCLUSION: 11C-ER176 displays a higher binding potential and a smaller variability of VT values. Thanks to these characteristics, clinical studies performed with 11C-ER176 are expected to have higher statistical power and thus require fewer subjects.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3411479
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 29
social impact