This paper discusses a sensorless control technique for synchronous reluctance machines based on an alternative way to process the information obtained from the stator current oversampling. The mathematical background is presented and demonstrated through experimental validation. Implementation issues are highlighted throughout the paper.

Sensorless Control for a Synchronous Reluctance Motor based on Current Oversampling using standard PWM excitation

M. Giuliato;F. Tinazzi;M. Zigliotto
2020

Abstract

This paper discusses a sensorless control technique for synchronous reluctance machines based on an alternative way to process the information obtained from the stator current oversampling. The mathematical background is presented and demonstrated through experimental validation. Implementation issues are highlighted throughout the paper.
2020
Proceedings of PEMD 2020
File in questo prodotto:
File Dimensione Formato  
pemd2020.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Preprint (submitted version)
Licenza: Accesso gratuito
Dimensione 2.61 MB
Formato Adobe PDF
2.61 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3438729
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact