Background: HyperDoppler is a new echocardiographic color Doppler-based technique that can assess intracardiac flow dynamics. The aim of this study was to verify the feasibility and reproducibility of this technique in unselected patients and its capability to differentiate measures of vortex flow within the left ventricle (LV) in normal sedentary subjects, athletes, and patients with heart failure. Methods: Two hundred unselected, consecutive patients presenting at the echocardiographic laboratory, 50 normal subjects, 30 athletes, and 50 patients with chronic heart failure and LV ejection fraction <50% were enrolled. Images were acquired using a MyLab X8 echo-scanner. Area, intensity, depth, length, and kinetic energy dissipation (KED) of vortex flow were measured. Results: The HyperDoppler technique feasibility was 94.5%. According to the intraclass correlation coefficient evaluations, repeatability and reproducibility of vortex flow measures were good for vortex area (0.82, 0.85), length (0.83, 0.82), and depth (0.87, 0.84) and excellent for intensity (0.92, 0.90) and KED (0.98, 0.98). Combining different vortex flow measures, the LV flow profile of healthy sedentary individuals, athletes, and heart failure patients could be differentiated. Conclusions: HyperDoppler is a feasible, reliable, and practical technique for the assessment of LV flow dynamics and may distinguish normal subjects and patients with heart failure.

Noninvasive Evaluation of Intraventricular Flow Dynamics by the HyperDoppler Technique: First Application to Normal Subjects, Athletes, and Patients with Heart Failure

Fiorencis, Andrea;Martini, Marika;Pergola, Valeria;Previtero, Marco;Iliceto, Sabino;Mele, Donato
2022

Abstract

Background: HyperDoppler is a new echocardiographic color Doppler-based technique that can assess intracardiac flow dynamics. The aim of this study was to verify the feasibility and reproducibility of this technique in unselected patients and its capability to differentiate measures of vortex flow within the left ventricle (LV) in normal sedentary subjects, athletes, and patients with heart failure. Methods: Two hundred unselected, consecutive patients presenting at the echocardiographic laboratory, 50 normal subjects, 30 athletes, and 50 patients with chronic heart failure and LV ejection fraction <50% were enrolled. Images were acquired using a MyLab X8 echo-scanner. Area, intensity, depth, length, and kinetic energy dissipation (KED) of vortex flow were measured. Results: The HyperDoppler technique feasibility was 94.5%. According to the intraclass correlation coefficient evaluations, repeatability and reproducibility of vortex flow measures were good for vortex area (0.82, 0.85), length (0.83, 0.82), and depth (0.87, 0.84) and excellent for intensity (0.92, 0.90) and KED (0.98, 0.98). Combining different vortex flow measures, the LV flow profile of healthy sedentary individuals, athletes, and heart failure patients could be differentiated. Conclusions: HyperDoppler is a feasible, reliable, and practical technique for the assessment of LV flow dynamics and may distinguish normal subjects and patients with heart failure.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3459131
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact