Compacted clay (CC) layers are commonly used as hydraulic barriers in landflls, thanks to their impervious capacity. However, mechanical and hydraulic properties of CC can be signifcantly afected by temperature variations due to the heat produced by waste degradation as well as to external air temperature and weathering. Previous experimental tests show that the most detrimental occurrence is the cyclic freezing–thawing (FT) that can increase the hydraulic conductivity of CC up to one order of magnitude. This paper aims at assessing the temperature distribution in a landfll multilayered top cover in several scenarios of temperature solicitations, in order to evaluate the depth of frost penetration. For this purpose, a 2D hydro-thermal coupled fnite element model representing a case study landfll top cover has been developed; each constituting layer has been characterized by physical and thermal properties acquired through direct measurements on sampled materials in unfrozen and frozen conditions. The model provides a reliable time description of the isotherm distribution within the layered top cover in several temperature scenarios typical of a temperate climate, thus estimating the penetration of the frost front as well as of high temperatures.

Assessment of frost and heating penetration in compacted clay layers of landfill top covers in temperate climate

Dalla Santa, Giorgia
;
Cola, Simonetta;Galgaro, Antonio
2022

Abstract

Compacted clay (CC) layers are commonly used as hydraulic barriers in landflls, thanks to their impervious capacity. However, mechanical and hydraulic properties of CC can be signifcantly afected by temperature variations due to the heat produced by waste degradation as well as to external air temperature and weathering. Previous experimental tests show that the most detrimental occurrence is the cyclic freezing–thawing (FT) that can increase the hydraulic conductivity of CC up to one order of magnitude. This paper aims at assessing the temperature distribution in a landfll multilayered top cover in several scenarios of temperature solicitations, in order to evaluate the depth of frost penetration. For this purpose, a 2D hydro-thermal coupled fnite element model representing a case study landfll top cover has been developed; each constituting layer has been characterized by physical and thermal properties acquired through direct measurements on sampled materials in unfrozen and frozen conditions. The model provides a reliable time description of the isotherm distribution within the layered top cover in several temperature scenarios typical of a temperate climate, thus estimating the penetration of the frost front as well as of high temperatures.
File in questo prodotto:
File Dimensione Formato  
DallaSanta et al_2022_frost penetration landfill cover.pdf

accesso aperto

Tipologia: Published (publisher's version)
Licenza: Creative commons
Dimensione 2.94 MB
Formato Adobe PDF
2.94 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3461119
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact