Voltage-controlled inverters (VCI) for distributed energy resources allow operation in grid-connected and islanded conditions. Common techniques based on P-f, Q-V droop-control use sinusoidal voltage references for the VCIs, which brings unwanted circulating harmonic currents in case of connection to grids with distorted voltage. In fact, the voltages at the point of common coupling (PCC) of a sub-grid, like a microgrid, are typically distorted, and the related circulating currents pose potential issues in terms of distribution and converters losses, effectiveness of protections, and power quality. This paper proposes a strategy to synthesize, at the output of a VCI, the same harmonic voltage detected at the PCC to limit unnecessary harmonic current circulation. The proposed method uses global positioning system (GPS) modules to synchronize the harmonic voltage references of the VCIs with the PCC. To this end, low-bandwidth communication is exploited to broadcast the information to distributed VCIs. An experimental setup is implemented to test the proposed control using a hardware-in-the-loop approach for the modeling of the power stage. Several case studies are analyzed, showing the effectiveness of the proposed strategy in achieving power quality improvements: reduced load voltage harmonics, reduced circulating currents, reduced grid current harmonic content, and reduced power losses.

Harmonic Voltage Synchronization Using GPS Modules for Grid-Connected Power Converters

Caldognetto T.
Conceptualization
;
Mattavelli P.
2022

Abstract

Voltage-controlled inverters (VCI) for distributed energy resources allow operation in grid-connected and islanded conditions. Common techniques based on P-f, Q-V droop-control use sinusoidal voltage references for the VCIs, which brings unwanted circulating harmonic currents in case of connection to grids with distorted voltage. In fact, the voltages at the point of common coupling (PCC) of a sub-grid, like a microgrid, are typically distorted, and the related circulating currents pose potential issues in terms of distribution and converters losses, effectiveness of protections, and power quality. This paper proposes a strategy to synthesize, at the output of a VCI, the same harmonic voltage detected at the PCC to limit unnecessary harmonic current circulation. The proposed method uses global positioning system (GPS) modules to synchronize the harmonic voltage references of the VCIs with the PCC. To this end, low-bandwidth communication is exploited to broadcast the information to distributed VCIs. An experimental setup is implemented to test the proposed control using a hardware-in-the-loop approach for the modeling of the power stage. Several case studies are analyzed, showing the effectiveness of the proposed strategy in achieving power quality improvements: reduced load voltage harmonics, reduced circulating currents, reduced grid current harmonic content, and reduced power losses.
File in questo prodotto:
File Dimensione Formato  
Harmonic_Voltage_Synchronization_Using_GPS_Modules_for_Grid-Connected_Power_Converters.pdf

accesso aperto

Tipologia: Published (Publisher's Version of Record)
Licenza: Creative commons
Dimensione 3.51 MB
Formato Adobe PDF
3.51 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3471141
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
  • OpenAlex 2
social impact