111Ag-perturbed angular correlation of gamma-rays (PAC) spectroscopy provides information on the nuclear quadrupole interactions, and thereby on the local structure and dynamics of the silver ion binding site. Brownian rotational motion, i.e. rotational diffusion, of 111Ag-labeled molecules will significantly affect the PAC spectra. Here we illustrate this effect, by simulating 111Ag PAC spectra for 111Ag-labeled molecules with molecular masses spanning from 102 to 106 g/mol, reflecting a span from fast (small molecules) to slow (large molecules) rotational diffusion on the PAC time scale. The simulated spectra are compared to 111Ag-PAC data obtained from a pilot study involving 111Ag(I) bound to a designed chelator exhibiting fast reorientation in solution, as well as to 111Ag-labeled species formed by 111Ag(I) in human serum, exhibiting slow (or no) reorientation on the PAC time scale. The simulated and experimental data illustrate typical PAC signals that are likely to be observed in vivo, when following the fate of 111Ag-labeled compounds. Potential in vivo applications are stability studies of 111Ag-radiopharmaceuticals, dissociation studies of 111Ag from the labeled molecule followed by binding to another (bio)molecule, or binding of 111Ag-labeled probes to larger carriers such as proteins.

Towards in vivo applications of 111-Ag perturbed angular correlation of γ-rays (PAC) spectroscopy

Tosato M.;Di Marco V.;
2022

Abstract

111Ag-perturbed angular correlation of gamma-rays (PAC) spectroscopy provides information on the nuclear quadrupole interactions, and thereby on the local structure and dynamics of the silver ion binding site. Brownian rotational motion, i.e. rotational diffusion, of 111Ag-labeled molecules will significantly affect the PAC spectra. Here we illustrate this effect, by simulating 111Ag PAC spectra for 111Ag-labeled molecules with molecular masses spanning from 102 to 106 g/mol, reflecting a span from fast (small molecules) to slow (large molecules) rotational diffusion on the PAC time scale. The simulated spectra are compared to 111Ag-PAC data obtained from a pilot study involving 111Ag(I) bound to a designed chelator exhibiting fast reorientation in solution, as well as to 111Ag-labeled species formed by 111Ag(I) in human serum, exhibiting slow (or no) reorientation on the PAC time scale. The simulated and experimental data illustrate typical PAC signals that are likely to be observed in vivo, when following the fate of 111Ag-labeled compounds. Potential in vivo applications are stability studies of 111Ag-radiopharmaceuticals, dissociation studies of 111Ag from the labeled molecule followed by binding to another (bio)molecule, or binding of 111Ag-labeled probes to larger carriers such as proteins.
File in questo prodotto:
File Dimensione Formato  
articolo.pdf

accesso aperto

Descrizione: articolo completo
Tipologia: Published (publisher's version)
Licenza: Creative commons
Dimensione 2.63 MB
Formato Adobe PDF
2.63 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3473190
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact