Thermal neutron detection is a key subject for nuclear physics research and also in a wide variety of applications from homeland security to nuclear medicine. In this work, it is proposed a novel flexible and conformable composite thermal neutron scintillator based on a fully enriched Lithium Tetraborate preparation (6Li210B4O7) combined with a phosphorescent inorganic scintillator powder (ZnS:Ag), and is then distributed into a polydimethylsiloxane matrix. The proposed scintillator shows a good neutron detection efficiency (max. ∼ 57% with respect to the commercial EJ-420), an average light output of ∼ 9000 ph/neutron-capture, a remarkable insensitivity to γ-rays (Gamma Rejection Ratio <10- 11), and an extraordinary flexibility, so as to reach extremely small curvature radii, down to 1.5 mm, with no signs of cracking or tearing. Its characteristics make it suitable to be employed in scenarios where non-standard geometries are needed, for example, to optimize the detector performance and/or maximize the detection efficiency. Finally, the response of a hybrid detector made of a plastic scintillator, wrapped with the proposed scintillator, coupled to a silicon photomultiplier array is described, and the excellent discrimination between γ-rays, fast and thermal neutrons resulting from data processing is demonstrated.

Novel flexible and conformable composite neutron scintillator based on fully enriched lithium tetraborate

Carturan S. M.;Mantovani G.;Fabris D.;Maggioni G.;Moretto S.
2023

Abstract

Thermal neutron detection is a key subject for nuclear physics research and also in a wide variety of applications from homeland security to nuclear medicine. In this work, it is proposed a novel flexible and conformable composite thermal neutron scintillator based on a fully enriched Lithium Tetraborate preparation (6Li210B4O7) combined with a phosphorescent inorganic scintillator powder (ZnS:Ag), and is then distributed into a polydimethylsiloxane matrix. The proposed scintillator shows a good neutron detection efficiency (max. ∼ 57% with respect to the commercial EJ-420), an average light output of ∼ 9000 ph/neutron-capture, a remarkable insensitivity to γ-rays (Gamma Rejection Ratio <10- 11), and an extraordinary flexibility, so as to reach extremely small curvature radii, down to 1.5 mm, with no signs of cracking or tearing. Its characteristics make it suitable to be employed in scenarios where non-standard geometries are needed, for example, to optimize the detector performance and/or maximize the detection efficiency. Finally, the response of a hybrid detector made of a plastic scintillator, wrapped with the proposed scintillator, coupled to a silicon photomultiplier array is described, and the excellent discrimination between γ-rays, fast and thermal neutrons resulting from data processing is demonstrated.
2023
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3479843
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact