The need for sustainable energy sources, as well as the current energetic crisis involving the majority of markets, has promoted the use of cryogenic liquefaction for the transportation and storage of natural gas (i.e., LNG). To guarantee the development of a robust and safe infrastructure, a complete understanding of the main phenomena occurring at low temperatures is paramount. In this sense, the largest grey areas are the characterization of the combustion at low-initial temperature and the interactions between water and cryogenic liquid. For these reasons, this work presents an experimental campaign on the possible mitigation strategies for the mitigation of consequences related to the accidental release of LNG. Particular emphasis was posed on the direct and indirect effects of water on cryogenic pool fire. The former resulted in a significant increase in the dimensions of fire (∼+50%) and burning rate (∼300%) with respect to the case with no direct contact between water and LNG, whereas the latter generated an abrupt decrease in the measured temperatures (<100 °C). The use of an emergency flare to empty an LNG tank was tested, as well. The spatial distribution of temperature was monitored along with the time to guarantee the safe operability of this equipment in the case of LNG combustion. The explanations for the observed phenomena and trends were provided, allowing for the development of safe procedures for the emergency response related to cryogenic fuels.

On the effectiveness of mitigation strategies for cryogenic applications

Mocellin, Paolo;Carboni, Mattia;Vianello, Chiara;
2023

Abstract

The need for sustainable energy sources, as well as the current energetic crisis involving the majority of markets, has promoted the use of cryogenic liquefaction for the transportation and storage of natural gas (i.e., LNG). To guarantee the development of a robust and safe infrastructure, a complete understanding of the main phenomena occurring at low temperatures is paramount. In this sense, the largest grey areas are the characterization of the combustion at low-initial temperature and the interactions between water and cryogenic liquid. For these reasons, this work presents an experimental campaign on the possible mitigation strategies for the mitigation of consequences related to the accidental release of LNG. Particular emphasis was posed on the direct and indirect effects of water on cryogenic pool fire. The former resulted in a significant increase in the dimensions of fire (∼+50%) and burning rate (∼300%) with respect to the case with no direct contact between water and LNG, whereas the latter generated an abrupt decrease in the measured temperatures (<100 °C). The use of an emergency flare to empty an LNG tank was tested, as well. The spatial distribution of temperature was monitored along with the time to guarantee the safe operability of this equipment in the case of LNG combustion. The explanations for the observed phenomena and trends were provided, allowing for the development of safe procedures for the emergency response related to cryogenic fuels.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0950423023001535-main.pdf

accesso aperto

Tipologia: Published (publisher's version)
Licenza: Creative commons
Dimensione 2.33 MB
Formato Adobe PDF
2.33 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3485001
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact