Laryngeal mask airway (LMA) may be considered by health caregivers of level I–II hospitals for neonatal resuscitation and stabilization before and during interhospital care, but literature provides little information on this aspect. This study reviewed the use of LMA during stabilization and transport in a large series of neonates. This is a retrospective study evaluating the use of LMA in infants who underwent emergency transport by the Eastern Veneto Neonatal Emergency Transport Service between January 2003 and December 2021. All data were obtained from transport registry, transport forms, and hospital charts. In total, 64/3252 transferred neonates (2%) received positive pressure ventilation with an LMA, with increasing trend over time (p = 0.001). Most of these neonates were transferred after birth (97%), due to a respiratory or neurologic disease (95%). LMA was used before the transport (n = 60), during the transport (n = 1), or both (n = 3). No device-related adverse effects were recorded. Sixty-one neonates (95%) survived and were discharged/transferred from the receiving center.
Laryngeal mask airway in neonatal stabilization and transport: a retrospective study.
Trevisanuto D.
2023
Abstract
Laryngeal mask airway (LMA) may be considered by health caregivers of level I–II hospitals for neonatal resuscitation and stabilization before and during interhospital care, but literature provides little information on this aspect. This study reviewed the use of LMA during stabilization and transport in a large series of neonates. This is a retrospective study evaluating the use of LMA in infants who underwent emergency transport by the Eastern Veneto Neonatal Emergency Transport Service between January 2003 and December 2021. All data were obtained from transport registry, transport forms, and hospital charts. In total, 64/3252 transferred neonates (2%) received positive pressure ventilation with an LMA, with increasing trend over time (p = 0.001). Most of these neonates were transferred after birth (97%), due to a respiratory or neurologic disease (95%). LMA was used before the transport (n = 60), during the transport (n = 1), or both (n = 3). No device-related adverse effects were recorded. Sixty-one neonates (95%) survived and were discharged/transferred from the receiving center.File | Dimensione | Formato | |
---|---|---|---|
s00431-023-05089-8.pdf
accesso aperto
Tipologia:
Published (publisher's version)
Licenza:
Creative commons
Dimensione
770.52 kB
Formato
Adobe PDF
|
770.52 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.