Signal injection sensor-less control for synchronous machines is known to be afflicted by an estimation error dependent on the load current. The estimation error is related to the cross- saturarion and the saliency of the adopted synchronous machine. A motor can be more or less suitable for signal injection sensorless control compared to other motors with different designs or sizes. A sensorless drive can even be afflicted by the control divergence when the machine is highly saturated, resulting in a useless drive. Moreover, even when the control converges, the actual current control trajectory is different from the given reference. In this paper, a measurement procedure of the convergence region, i.e. the operating points where the motor can be successfully controlled without a position sensor is presented and validated. In particular, two different synchronous motors are considered, a permanent magnet assisted synchronous reluctance motor (PMA-SynRM) and a synchronous reluctance motor (SynRM)

Measurement of the Self-Sensing Capability of Synchronous Machines for High Frequency Signal Injection Sensorless Drives

Alberti, Luigi
;
2023

Abstract

Signal injection sensor-less control for synchronous machines is known to be afflicted by an estimation error dependent on the load current. The estimation error is related to the cross- saturarion and the saliency of the adopted synchronous machine. A motor can be more or less suitable for signal injection sensorless control compared to other motors with different designs or sizes. A sensorless drive can even be afflicted by the control divergence when the machine is highly saturated, resulting in a useless drive. Moreover, even when the control converges, the actual current control trajectory is different from the given reference. In this paper, a measurement procedure of the convergence region, i.e. the operating points where the motor can be successfully controlled without a position sensor is presented and validated. In particular, two different synchronous motors are considered, a permanent magnet assisted synchronous reluctance motor (PMA-SynRM) and a synchronous reluctance motor (SynRM)
File in questo prodotto:
File Dimensione Formato  
Measurement_of_the_Self-Sensing_Capability_of_Synchronous_Machines_for_High_Frequency_Signal_Injection_Sensorless_Drives.pdf

accesso aperto

Tipologia: Published (publisher's version)
Licenza: Creative commons
Dimensione 3.64 MB
Formato Adobe PDF
3.64 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3495180
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact