Aim: To provide a preliminary evaluation of the accuracy and safety of Gluclas decision support system suggestions in a hypoglycaemic clamp study. Methods: This analysis was performed using data from 32 participants (four groups with different glucose-insulin regulation: post Roux-en-Y gastric bypass with and without postprandial hypoglycaemia syndrome, postsleeve gastrectomy and non-operated controls) undergoing Gluclas-assisted hypoglycaemic clamps (target: 2.5 mmol/L for 20 minutes at 150 minutes after oral glucose ingestion). Gluclas provided glucose infusion rate suggestions upon manual entry of blood glucose values (every 5 minutes), which were either followed or overruled by investigators after critical review. Accuracy and safety were evaluated by mean absolute error (MAE), mean absolute percentage error (MAPE), average glucose level, coefficient of variation (CV) and minimal glucose level during the 20-minute hypoglycaemic period. Results: Investigators accepted 84% of suggestions, with a mean deviation of 30.33 mg/min. During the hypoglycaemic period, the MAE was 0.16 (0.12-0.24) (median [interquartile range]) mmol/L and the MAPE was 6.12% (4.80%-9.29%). CV was 4.90% (3.58%-7.27%), with 5% considered the threshold for sufficient quality. The minimal glucose level was 2.40 (2.30-2.50) mmol/L. Conclusions: Gluclas achieved sufficiently high accuracy with minimal safety risks in a population with differences in glucose-insulin dynamics, underscoring its applicability to various patient groups.

Clinical evaluation of a decision support system for glucose infusion in hypoglycaemic clamp experiments

Pavan J.;Dalla Man C.;Del Favero S.
2023

Abstract

Aim: To provide a preliminary evaluation of the accuracy and safety of Gluclas decision support system suggestions in a hypoglycaemic clamp study. Methods: This analysis was performed using data from 32 participants (four groups with different glucose-insulin regulation: post Roux-en-Y gastric bypass with and without postprandial hypoglycaemia syndrome, postsleeve gastrectomy and non-operated controls) undergoing Gluclas-assisted hypoglycaemic clamps (target: 2.5 mmol/L for 20 minutes at 150 minutes after oral glucose ingestion). Gluclas provided glucose infusion rate suggestions upon manual entry of blood glucose values (every 5 minutes), which were either followed or overruled by investigators after critical review. Accuracy and safety were evaluated by mean absolute error (MAE), mean absolute percentage error (MAPE), average glucose level, coefficient of variation (CV) and minimal glucose level during the 20-minute hypoglycaemic period. Results: Investigators accepted 84% of suggestions, with a mean deviation of 30.33 mg/min. During the hypoglycaemic period, the MAE was 0.16 (0.12-0.24) (median [interquartile range]) mmol/L and the MAPE was 6.12% (4.80%-9.29%). CV was 4.90% (3.58%-7.27%), with 5% considered the threshold for sufficient quality. The minimal glucose level was 2.40 (2.30-2.50) mmol/L. Conclusions: Gluclas achieved sufficiently high accuracy with minimal safety risks in a population with differences in glucose-insulin dynamics, underscoring its applicability to various patient groups.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3507760
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact