Aim: To investigate the efficacy and safety profile of T-shaped pars plana scleral incision technique in removing large intraocular foreign bodies, during 23-gauge pars plana vitrectomy. Methods: Retrospective interventional case series that included patients diagnosed with a large intraocular foreign body (IOFB). Possible postoperative complications were recorded 24 h, 1 month, 3 and 6 months postoperatively. Results: Thirty eyes of 30 patients (48 ± 5 years old) were enrolled. All IOFBs were successfully removed: mean diameters of 7.8 ± 2.0 mm and 2.6 ± 0.3 mm. Silicone oil and sulfur hexafluoride were used in 27 and 3 eyes, respectively. Lensectomy was performed in 27 eyes. Intraocular lens was implanted at first attempt in 12 eyes; during a second operation in 12 eyes and 6 eyes remained aphakic. At any follow-up, no signs of postoperative complications were observed. Secondary retinal detachment occurred in 12 eyes. Mean preoperative corrected distance visual acuity was 0.04, on t...
T-shaped pars plana scleral incision to remove large intraocular foreign body
Lorenzo Motta
Conceptualization
;
2024
Abstract
Aim: To investigate the efficacy and safety profile of T-shaped pars plana scleral incision technique in removing large intraocular foreign bodies, during 23-gauge pars plana vitrectomy. Methods: Retrospective interventional case series that included patients diagnosed with a large intraocular foreign body (IOFB). Possible postoperative complications were recorded 24 h, 1 month, 3 and 6 months postoperatively. Results: Thirty eyes of 30 patients (48 ± 5 years old) were enrolled. All IOFBs were successfully removed: mean diameters of 7.8 ± 2.0 mm and 2.6 ± 0.3 mm. Silicone oil and sulfur hexafluoride were used in 27 and 3 eyes, respectively. Lensectomy was performed in 27 eyes. Intraocular lens was implanted at first attempt in 12 eyes; during a second operation in 12 eyes and 6 eyes remained aphakic. At any follow-up, no signs of postoperative complications were observed. Secondary retinal detachment occurred in 12 eyes. Mean preoperative corrected distance visual acuity was 0.04, on t...File | Dimensione | Formato | |
---|---|---|---|
9_MDTfmed-11-1399321.pdf
accesso aperto
Tipologia:
Published (Publisher's Version of Record)
Licenza:
Creative commons
Dimensione
578.3 kB
Formato
Adobe PDF
|
578.3 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.