Effects of coatings on the quality factor of quartz crystal resonators operating at liquid helium temperature are analyzed. A first set of tests demonstrates the effects of gold and chromium electrodes at low temperature. The second set of tests involves a multilayer tantala/silica coating used to reach an extreme reflectance on mirrors such those used in optical cavities or Michelson interferometers. Mechanical losses are measured and discussed from the theoretical model the most frequently used.

Impact of coatings on the quality factor of a quartz crystal resonator at liquid helium temperature

Cagnoli G.
2016

Abstract

Effects of coatings on the quality factor of quartz crystal resonators operating at liquid helium temperature are analyzed. A first set of tests demonstrates the effects of gold and chromium electrodes at low temperature. The second set of tests involves a multilayer tantala/silica coating used to reach an extreme reflectance on mirrors such those used in optical cavities or Michelson interferometers. Mechanical losses are measured and discussed from the theoretical model the most frequently used.
2016
2016 IEEE International Frequency Control Symposium, IFCS 2016 - Proceedings
70th IEEE International Frequency Control Symposium, IFCS 2016
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3578068
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact