No data have been published on real cardiac assistance with demand dynamic cardiomyoplasty. We tested the utility of a Doppler flow wire in measuring beat by beat aortic flow velocity and evaluating cardiac assistance in demand cardiomyoplasty patients. The technique was tested in seven patients (M/W = 6/1; age, 57.1 ± 6.2 years; atrial fibrillation/sinus rhythm = 1/6; New York Heart Association [NYHA] classification = 1.4 ± 0.5). Measurements were done using a 0.018 inch peripheral Doppler flow wire advanced through a 5 French arterial femoral sheath. Three 1 minute periods with the stimulator off, and three 1 minute periods with clinical stimulation were recorded. We measured peak aortic flow velocity in all beats. Latissimus dorsi mechanogram was simultaneously recorded. Comparison between preoperative and follow-up data showed significantly higher values of tetanic fusion frequency and ejection fraction at follow-up, whereas mean NYHA class was significantly lower. Statistical anal...

New advances in dynamic cardiomyoplasty: Doppler flow wire shows improved cardiac assistance in demand protocol

CARRARO, UGO;
2002

Abstract

No data have been published on real cardiac assistance with demand dynamic cardiomyoplasty. We tested the utility of a Doppler flow wire in measuring beat by beat aortic flow velocity and evaluating cardiac assistance in demand cardiomyoplasty patients. The technique was tested in seven patients (M/W = 6/1; age, 57.1 ± 6.2 years; atrial fibrillation/sinus rhythm = 1/6; New York Heart Association [NYHA] classification = 1.4 ± 0.5). Measurements were done using a 0.018 inch peripheral Doppler flow wire advanced through a 5 French arterial femoral sheath. Three 1 minute periods with the stimulator off, and three 1 minute periods with clinical stimulation were recorded. We measured peak aortic flow velocity in all beats. Latissimus dorsi mechanogram was simultaneously recorded. Comparison between preoperative and follow-up data showed significantly higher values of tetanic fusion frequency and ejection fraction at follow-up, whereas mean NYHA class was significantly lower. Statistical anal...
2002
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/1340466
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
  • OpenAlex ND
social impact