The BNCT radiation field is complex because different beam components are mixed, each one having different relative biological effectiveness (RBE). Microdosimetry with tissue-equivalent proportional counters (TEPC) has proven to be an ideal dosimetric technique for mixed radiation fields, because it is able both to measure the absorbed dose and to assess the radiation field relative biological effectiveness with good accuracy. An ideal detector for BNCT should contain two TEPCs, one detector loaded with, while the other one without (10)B in order to record all beam components with a unique measurement. Moreover, Such a detector should be of tiny size in order to be able to measure in the intense BNCT radiation fields without significant pile-up effects. TEPCs have been shown to be pretty good dosimeters for mixed radiation fields. In this paper the first mini twin TEPC counter for BNCT is presented, as well as first measurement at the new HYTHOR thermal irradiation facility at TAPIRO nuclear reactor and comparison with related Monte Carlo calculations.

BNCT dosimetry performed with a mini twin tissue-equivalent proportional counters (TEPC)

MORO, DAVIDE;DE NARDO, LAURA;
2009

Abstract

The BNCT radiation field is complex because different beam components are mixed, each one having different relative biological effectiveness (RBE). Microdosimetry with tissue-equivalent proportional counters (TEPC) has proven to be an ideal dosimetric technique for mixed radiation fields, because it is able both to measure the absorbed dose and to assess the radiation field relative biological effectiveness with good accuracy. An ideal detector for BNCT should contain two TEPCs, one detector loaded with, while the other one without (10)B in order to record all beam components with a unique measurement. Moreover, Such a detector should be of tiny size in order to be able to measure in the intense BNCT radiation fields without significant pile-up effects. TEPCs have been shown to be pretty good dosimeters for mixed radiation fields. In this paper the first mini twin TEPC counter for BNCT is presented, as well as first measurement at the new HYTHOR thermal irradiation facility at TAPIRO nuclear reactor and comparison with related Monte Carlo calculations.
2009
File in questo prodotto:
File Dimensione Formato  
ARI4530.pdf

Accesso riservato

Tipologia: Published (Publisher's Version of Record)
Licenza: Accesso privato - non pubblico
Dimensione 444.27 kB
Formato Adobe PDF
444.27 kB Adobe PDF Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2377510
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 21
  • OpenAlex 28
social impact