Objective. Up to now, no validated tools are in use for the assessment of the skin lesions in localized scleroderma (LS). The aim of this study is to evaluate the performance of a new computerized skin score (CSS) method for the measurement of circumscribed lesions in LS. Methods. The study consisted of three phases: set up of the CSS technique, measurement of target lesions of LS patients, assessment of intra- and inter-rater reliability. The CSS technique consists in delimitating the indurate lesion on an adhesive transparent film, transferring it over a cardboard and then calculating the affected area with a specifically created software. The technique was explained to a panel of 10 physicians with different expertise in LS (three paediatric rheumatologists, two dermatologists, five paediatric residents). All participants, singularly and blindly to the others, examined 10 consecutive patients twice after a time interval of at least 6 h. The intra-observer variability was evaluated by the repeatability coefficient and the inter-rater reliability by the intra-class correlation coefficient (ICC). Results. The repeatability coefficients were good, ranging between 1.90 and 7.03. The mean values of skin scores were not significantly different among the examiners. The ICC for indurate area calculation were high in both the experts (0.97) and the residents (0.91–0.94). Conclusions. CSS has shown to be a reliable method to assess the skin lesions in patients with LS. It is reproducible, easy to use and, with the support of the CSS software, applicable worldwide.

A new computerized method for the assessment of skin lesions in Localized Scleroderma

ZULIAN, FRANCESCO;GRISAN, ENRICO;FRIGO, ANNA CHIARA;RUGGERI, ALFREDO;BELLONI FORTINA, ANNA
2007

Abstract

Objective. Up to now, no validated tools are in use for the assessment of the skin lesions in localized scleroderma (LS). The aim of this study is to evaluate the performance of a new computerized skin score (CSS) method for the measurement of circumscribed lesions in LS. Methods. The study consisted of three phases: set up of the CSS technique, measurement of target lesions of LS patients, assessment of intra- and inter-rater reliability. The CSS technique consists in delimitating the indurate lesion on an adhesive transparent film, transferring it over a cardboard and then calculating the affected area with a specifically created software. The technique was explained to a panel of 10 physicians with different expertise in LS (three paediatric rheumatologists, two dermatologists, five paediatric residents). All participants, singularly and blindly to the others, examined 10 consecutive patients twice after a time interval of at least 6 h. The intra-observer variability was evaluated by the repeatability coefficient and the inter-rater reliability by the intra-class correlation coefficient (ICC). Results. The repeatability coefficients were good, ranging between 1.90 and 7.03. The mean values of skin scores were not significantly different among the examiners. The ICC for indurate area calculation were high in both the experts (0.97) and the residents (0.91–0.94). Conclusions. CSS has shown to be a reliable method to assess the skin lesions in patients with LS. It is reproducible, easy to use and, with the support of the CSS software, applicable worldwide.
2007
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2447124
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 61
  • ???jsp.display-item.citation.isi??? 49
social impact