Track-nanodosimetry has the objective to investigate the stochastic aspect of ionisation events in particle tracks, by evaluating the probability distribution of the number of ionisations produced in a nanometric target volume positioned at distance d from a particle track. Such kind of measurements makes use of electron (or ion) gas detectors with detecting efficiencies non-uniformly distributed inside the target volume. This fact makes the reconstruction of true ionisation distributions, which correspond to an ideal efficiency of 100%, non-trivial. Bayesian unfolding has been applied to ionisation distributions produced by 5.4 MeV alpha particles and 20 MeV protons in cylindrical volumes of propane of 20 nm equivalent size, positioned at different impact parameters with respect to the primary beam. It will be shown that a Bayesian analysis performed by subdividing the target volume in sub-regions of different detection efficiencies is able to provide a good reconstruction of the true nanodosimetric ionisation distributions.

BAYESIAN ANALYSIS OF NANODOSIMETRIC IONISATION DISTRIBUTIONS DUE TO ALPHA PARTICLES AND PROTONS

DE NARDO, LAURA;
2011

Abstract

Track-nanodosimetry has the objective to investigate the stochastic aspect of ionisation events in particle tracks, by evaluating the probability distribution of the number of ionisations produced in a nanometric target volume positioned at distance d from a particle track. Such kind of measurements makes use of electron (or ion) gas detectors with detecting efficiencies non-uniformly distributed inside the target volume. This fact makes the reconstruction of true ionisation distributions, which correspond to an ideal efficiency of 100%, non-trivial. Bayesian unfolding has been applied to ionisation distributions produced by 5.4 MeV alpha particles and 20 MeV protons in cylindrical volumes of propane of 20 nm equivalent size, positioned at different impact parameters with respect to the primary beam. It will be shown that a Bayesian analysis performed by subdividing the target volume in sub-regions of different detection efficiencies is able to provide a good reconstruction of the true nanodosimetric ionisation distributions.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2479362
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact