The aim of the study was to determine the comparability of the true dry matter digestibility (TDMd) achieved in situ with either traditional nylon bags (IS nylon) or synthetic filter bags (IS filter), and in vitro with either conventional bottles (CB) or the DaisyII incubation technique, using rumen fluid collected by oro-ruminal suction from intact cows. The four TDMd results were compared by linear regression. For each method, 11 feeds were incubated for 48 h in two separate incubations. The reproducibility of TDMd measurements was 97.9%, 95.1%, 98.8% and 96.0% for IS nylon, IS filter, CB and DaisyII, respectively. The determination coefficient, the slope (b), and the significant difference of the slope from unity, of the linear relationship betweenTDMdvalues (g/kgDM)were as follows: IS nylon v. IS filter, R2 = 0.97, b = 0.86, P = 0.02; IS nylon v. CB,R2= 0.90, b =1.02,P=0.27; IS nylon v. DaisyII,R2= 0.90, b = 1.06,P< 0.01; and IS filter v. DaisyII,R2=0.95, b = 0.98, P = 0.13. In situ filter bags and DaisyII underestimated the TDMd values compared with IS nylon bags and CB, respectively. In situ, the replacement of nylon withfilter bags could simplify the procedure of analysis, with less manipulation of residuals and less labour, and offers the possibility to increase the number of samples analysed simultaneously. The close relationships found among methods suggest that rumen fluid collected from intact cows can produce in vitro estimates of TDMd at 48 h well correlated with those obtained in situ.

True dry matter digestibility of feeds evaluated in situ with different bags and in vitro using rumen fluid collected from intact donor cows

TAGLIAPIETRA, FRANCO;CATTANI, MIRKO;BAILONI, LUCIA;SCHIAVON, STEFANO
2012

Abstract

The aim of the study was to determine the comparability of the true dry matter digestibility (TDMd) achieved in situ with either traditional nylon bags (IS nylon) or synthetic filter bags (IS filter), and in vitro with either conventional bottles (CB) or the DaisyII incubation technique, using rumen fluid collected by oro-ruminal suction from intact cows. The four TDMd results were compared by linear regression. For each method, 11 feeds were incubated for 48 h in two separate incubations. The reproducibility of TDMd measurements was 97.9%, 95.1%, 98.8% and 96.0% for IS nylon, IS filter, CB and DaisyII, respectively. The determination coefficient, the slope (b), and the significant difference of the slope from unity, of the linear relationship betweenTDMdvalues (g/kgDM)were as follows: IS nylon v. IS filter, R2 = 0.97, b = 0.86, P = 0.02; IS nylon v. CB,R2= 0.90, b =1.02,P=0.27; IS nylon v. DaisyII,R2= 0.90, b = 1.06,P< 0.01; and IS filter v. DaisyII,R2=0.95, b = 0.98, P = 0.13. In situ filter bags and DaisyII underestimated the TDMd values compared with IS nylon bags and CB, respectively. In situ, the replacement of nylon withfilter bags could simplify the procedure of analysis, with less manipulation of residuals and less labour, and offers the possibility to increase the number of samples analysed simultaneously. The close relationships found among methods suggest that rumen fluid collected from intact cows can produce in vitro estimates of TDMd at 48 h well correlated with those obtained in situ.
2012
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2493835
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 18
social impact