Visible and near infrared reflectance (Vis-NIR, 350 to 1800 nm), and near infrared transmittance (NIT, 850 to 1050 nm) spectroscopy were used to predict beef quality traits of intact and ground meat samples. Calibration equations were developed from reference data (n=312) of pH, color traits (L*, a*, and b*), ageing loss (%), cooking loss (%), and Warner–Bratzler shear force (WBSF, N) using partial least squares regressions. Predictive ability of the models was assessed by coefficient of determination of cross-validation (R2CV) and root mean square error of cross-validation. Quality traits were better predicted on intact than on ground samples, and the best results were obtained using Vis-NIR spectroscopy. Predictions were good (R2CV=0.62 to 0.73) for pH, L*, and a*, hardly sufficient (R2CV=0.34 to 0.60) for b*, cooking loss, and WBSF, and unsatisfactory for ageing loss (R2CV=0.15). Vis-NIR spectroscopy might be used to predict some physical beef quality traits on intact meat samples.
The relevance of different near infrared technologies and sample treatments for predicting meat quality traits in commercial beef cuts
DE MARCHI, MASSIMO;PENASA, MAURO;CECCHINATO, ALESSIO;BITTANTE, GIOVANNI
2013
Abstract
Visible and near infrared reflectance (Vis-NIR, 350 to 1800 nm), and near infrared transmittance (NIT, 850 to 1050 nm) spectroscopy were used to predict beef quality traits of intact and ground meat samples. Calibration equations were developed from reference data (n=312) of pH, color traits (L*, a*, and b*), ageing loss (%), cooking loss (%), and Warner–Bratzler shear force (WBSF, N) using partial least squares regressions. Predictive ability of the models was assessed by coefficient of determination of cross-validation (R2CV) and root mean square error of cross-validation. Quality traits were better predicted on intact than on ground samples, and the best results were obtained using Vis-NIR spectroscopy. Predictions were good (R2CV=0.62 to 0.73) for pH, L*, and a*, hardly sufficient (R2CV=0.34 to 0.60) for b*, cooking loss, and WBSF, and unsatisfactory for ageing loss (R2CV=0.15). Vis-NIR spectroscopy might be used to predict some physical beef quality traits on intact meat samples.| File | Dimensione | Formato | |
|---|---|---|---|
|
De Marchi M et al 2013 - Different near infrared technologies and sample treatments to predict meat quality traits - MEAT SCI.pdf
Accesso riservato
Tipologia:
Published (Publisher's Version of Record)
Licenza:
Accesso privato - non pubblico
Dimensione
889.33 kB
Formato
Adobe PDF
|
889.33 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.




