Control of blood glucose concentration for patients in intensive care units (ICUs) has been demonstrated to be beneficial in reducing mortality and the incidence of serious complications, for both diabetic and non-diabetic patients. However, the high degree of variability and uncertainty characterizing the physiological conditions of critically ill subjects makes automated glucose control quite difficult; consequently, traditional, nurse-implemented protocols are widely employed. These protocols are based on infrequent glucose measurements, look-up tables to determine the appropriate insulin infusion rates, and bedside insulin administration. In this paper, a novel automatic adaptive control strategy based on frequent glucose measurements and a self-tuning control technique is validated based on a simulation study for 200 virtual patients. The adaptive control strategy is shown to be highly effective in controlling blood glucose concentration despite the large degree of variability in the blood glucose response exhibited by the 200 simulated patients.

Adaptive blood glucose control for intensive care applications

OTTAVIAN, MATTEO;BAROLO, MASSIMILIANO;
2013

Abstract

Control of blood glucose concentration for patients in intensive care units (ICUs) has been demonstrated to be beneficial in reducing mortality and the incidence of serious complications, for both diabetic and non-diabetic patients. However, the high degree of variability and uncertainty characterizing the physiological conditions of critically ill subjects makes automated glucose control quite difficult; consequently, traditional, nurse-implemented protocols are widely employed. These protocols are based on infrequent glucose measurements, look-up tables to determine the appropriate insulin infusion rates, and bedside insulin administration. In this paper, a novel automatic adaptive control strategy based on frequent glucose measurements and a self-tuning control technique is validated based on a simulation study for 200 virtual patients. The adaptive control strategy is shown to be highly effective in controlling blood glucose concentration despite the large degree of variability in the blood glucose response exhibited by the 200 simulated patients.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2553884
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 7
social impact