Functional quantification with PET is generally based on modeling that assumes tissue regions are kinetically homogeneous. Even in regions sufficiently small to approach homogeneity, spillover due to resolution limitations of PET scanners may introduce heterogeneous kinetics into measured data. Herein we consider effects of kinetic heterogeneity at the smallest volume accessible, the single image voxel. We used L-[1-11C]leucine PET and compared rates of cerebral protein synthesis (rCPS) estimated voxelwise with methods that do (Spectral Analysis Iterative Filter, SAIF) and do not (Basis Function Method, BFM) allow for kinetic heterogeneity. In high resolution PET data with good counting statistics BFM produced estimates of rCPS comparable to SAIF, but at lower computational cost; thus the simpler, less costly method can be applied. With poorer counting statistics (lower injected radiotracer doses), BFM estimates were more biased. In data smoothed to simulate lower resolution PET, BFM produced estimates of rCPS 9-14% higher than SAIF, overestimation consistent with applying a homogeneous tissue model to kinetically heterogeneous data. Hence with lower resolution data it is necessary to account for kinetic heterogeneity in the analysis. Kinetic heterogeneity may impact analyses of other tracers and scanning protocols differently; assessments should be made on a case by case basis.

Impact of tissue kinetic heterogeneity on PET quantification: case study with the L-[1-C-11]leucine PET method for cerebral protein synthesis rates

Veronese, Mattia;Bertoldo, Alessandra
Writing – Review & Editing
;
2018

Abstract

Functional quantification with PET is generally based on modeling that assumes tissue regions are kinetically homogeneous. Even in regions sufficiently small to approach homogeneity, spillover due to resolution limitations of PET scanners may introduce heterogeneous kinetics into measured data. Herein we consider effects of kinetic heterogeneity at the smallest volume accessible, the single image voxel. We used L-[1-11C]leucine PET and compared rates of cerebral protein synthesis (rCPS) estimated voxelwise with methods that do (Spectral Analysis Iterative Filter, SAIF) and do not (Basis Function Method, BFM) allow for kinetic heterogeneity. In high resolution PET data with good counting statistics BFM produced estimates of rCPS comparable to SAIF, but at lower computational cost; thus the simpler, less costly method can be applied. With poorer counting statistics (lower injected radiotracer doses), BFM estimates were more biased. In data smoothed to simulate lower resolution PET, BFM produced estimates of rCPS 9-14% higher than SAIF, overestimation consistent with applying a homogeneous tissue model to kinetically heterogeneous data. Hence with lower resolution data it is necessary to account for kinetic heterogeneity in the analysis. Kinetic heterogeneity may impact analyses of other tracers and scanning protocols differently; assessments should be made on a case by case basis.
2018
File in questo prodotto:
File Dimensione Formato  
s41598-017-18890-x.pdf

accesso aperto

Tipologia: Published (publisher's version)
Licenza: Creative commons
Dimensione 3.64 MB
Formato Adobe PDF
3.64 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3262683
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact