Knowledge about fasciae has become increasingly relevant in connection to regional anesthesiology, given the growing interest in fascial plane, interfascial, and nerve blocks. Ultrasound (US) imaging, thanks to high definition, provides the possibility to visualize and measure their thickness. The purpose of this study was to measure and compare, by US imaging, the thickness of deep/muscular fasciae in different points of the arm and forearm. An observational study has been performed using US imaging to measure brachial and antebrachial fasciae thickness at anterior and posterior regions, respectively, of the arm and forearm at different levels with a new protocol in a sample of 25 healthy volunteers. Results of fascial thickness revealed statistically significant differences (p < 0.0001) in the brachial fascia between the anterior and the posterior regions; in terms of the antebrachial fascia, no statistically significant difference was present (p > 0.05) between the regions/levels. Moreover, regarding the posterior region/levels, the brachial fascia had a greater thickness (mean 0.81 ± 0.20 mm) than the antebrachial fascia (mean 0.71 ± 0.20 mm); regarding the anterior region/levels, the antebrachial fascia was thicker (mean 0.70 ± 0.2 mm) than the brachial fascia (mean 0.61 ± 0.11 mm). In addition, the intra-rater reliability reported good reliability (ICC2,k: 0.88). US imaging helps to improve grading of fascial dysfunction or disease by revealing subclinical lesions, clinically invisible fascial changes, and one of the US parameters to reliably evaluate is the thickness in the different regions and levels.

Ultrasound imaging of Brachial and antebrachial Fasciae

Pirri C.;Guidolin D.;Fede C.;Macchi V.;De Caro R.;Stecco C.
2021

Abstract

Knowledge about fasciae has become increasingly relevant in connection to regional anesthesiology, given the growing interest in fascial plane, interfascial, and nerve blocks. Ultrasound (US) imaging, thanks to high definition, provides the possibility to visualize and measure their thickness. The purpose of this study was to measure and compare, by US imaging, the thickness of deep/muscular fasciae in different points of the arm and forearm. An observational study has been performed using US imaging to measure brachial and antebrachial fasciae thickness at anterior and posterior regions, respectively, of the arm and forearm at different levels with a new protocol in a sample of 25 healthy volunteers. Results of fascial thickness revealed statistically significant differences (p < 0.0001) in the brachial fascia between the anterior and the posterior regions; in terms of the antebrachial fascia, no statistically significant difference was present (p > 0.05) between the regions/levels. Moreover, regarding the posterior region/levels, the brachial fascia had a greater thickness (mean 0.81 ± 0.20 mm) than the antebrachial fascia (mean 0.71 ± 0.20 mm); regarding the anterior region/levels, the antebrachial fascia was thicker (mean 0.70 ± 0.2 mm) than the brachial fascia (mean 0.61 ± 0.11 mm). In addition, the intra-rater reliability reported good reliability (ICC2,k: 0.88). US imaging helps to improve grading of fascial dysfunction or disease by revealing subclinical lesions, clinically invisible fascial changes, and one of the US parameters to reliably evaluate is the thickness in the different regions and levels.
2021
File in questo prodotto:
File Dimensione Formato  
diagnostics-11-02261-v2.pdf

accesso aperto

Tipologia: Published (publisher's version)
Licenza: Creative commons
Dimensione 1.7 MB
Formato Adobe PDF
1.7 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3411598
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact