RFX-mod2 is an upgrade of RFX-mod that will use a modified shell and mechanical structure in order to enhance plasma-shell proximity and therefore to improve plasma control. The Control and Data Acquisition System for most of the plant systems and diagnostics previously used in RFX-mod will be refurbished, while others will be completely re-built. The most important component that will be completely renewed is the ElectroMagnetic probe (EM) data acquisition system, where a new architecture based on XILINX Zynq FPGA will be used to carry out at the same time both high-speed data acquisition and resampled data streaming for active plasma control. The use of MDSplus will be retained in RFX-mod2, while the MARTe framework used for real-time plasma control will be replaced by MARTe2, a new framework developed under strict software quality standards. Plant control in RFX-mod2 will be supervised by WinCC-OA, replacing the previous FactoryLink SCADA systems. Older plant systems such as vacuum control based on outdated S5 PLCs will be updated and will use OPC-UA for communication with the supervisory control system.

The upgrade of the control and data acquisition system of RFXMod2

Manduchi, G;Luchetta, A;Rigoni, A;Martini, G;Ferron, N;Barbato, P;Capobianco, R;Molon, F;Moressa, M;Simionato, P;
2021

Abstract

RFX-mod2 is an upgrade of RFX-mod that will use a modified shell and mechanical structure in order to enhance plasma-shell proximity and therefore to improve plasma control. The Control and Data Acquisition System for most of the plant systems and diagnostics previously used in RFX-mod will be refurbished, while others will be completely re-built. The most important component that will be completely renewed is the ElectroMagnetic probe (EM) data acquisition system, where a new architecture based on XILINX Zynq FPGA will be used to carry out at the same time both high-speed data acquisition and resampled data streaming for active plasma control. The use of MDSplus will be retained in RFX-mod2, while the MARTe framework used for real-time plasma control will be replaced by MARTe2, a new framework developed under strict software quality standards. Plant control in RFX-mod2 will be supervised by WinCC-OA, replacing the previous FactoryLink SCADA systems. Older plant systems such as vacuum control based on outdated S5 PLCs will be updated and will use OPC-UA for communication with the supervisory control system.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3460873
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact