The correct identification and quantification of mono-ortho and coplanar congeners allows the attribution of the WHO-TEFs (Van den Berg et al., 1998) and to calculate the TEQs. A rapid analytical method for PCBs and hexachlorobenzene determination was tuned. Briefly it consisted of: a) sample previously lyophilized was submitted in a ratio 1/10 (w/v) to solvent fat extraction (hexane/acetone, 50/50 v/v); b) the fat recovered was diluted 1/5 with 13C HCB and PCBs isotopes; c) to remove fat and other source of interference, HPLC pre-separation was achieved using a silica column and a three way valve; d) the GC separation was conducted by on-column injection into ZB5MS column (Zebron, 60 m, 0.25 mm i.d., 0.25 μm film thickness) while detection operated in negative chemical ionization SIM mode using methane as reagent gas. As regard quality analysis percent recovery was nearly 100%, repeatability was <10% (as relative standard deviation) and LOQ was 0.2 pg g-1 (w.w.). Farm reared and wild fish, coming from several areas of Mediterranean Sea, were analyzed. The sum of total DL-PCBs ranged from 0.22 to 6.33 ng g-1 (w.w.) for farm reared fish and from 0.04 to 12.96 ng g-1 (w.w.) for wild fish.

Rapid dioxin-like polychlorinated biphenyls (DL-PCBs) and hexachlorobenzene (HCB) determination in fish by HPLC-GC-MS negative chemical ionization mode

NOVELLI, ENRICO;BALZAN, STEFANIA;SEGATO, SEVERINO;
2007

Abstract

The correct identification and quantification of mono-ortho and coplanar congeners allows the attribution of the WHO-TEFs (Van den Berg et al., 1998) and to calculate the TEQs. A rapid analytical method for PCBs and hexachlorobenzene determination was tuned. Briefly it consisted of: a) sample previously lyophilized was submitted in a ratio 1/10 (w/v) to solvent fat extraction (hexane/acetone, 50/50 v/v); b) the fat recovered was diluted 1/5 with 13C HCB and PCBs isotopes; c) to remove fat and other source of interference, HPLC pre-separation was achieved using a silica column and a three way valve; d) the GC separation was conducted by on-column injection into ZB5MS column (Zebron, 60 m, 0.25 mm i.d., 0.25 μm film thickness) while detection operated in negative chemical ionization SIM mode using methane as reagent gas. As regard quality analysis percent recovery was nearly 100%, repeatability was <10% (as relative standard deviation) and LOQ was 0.2 pg g-1 (w.w.). Farm reared and wild fish, coming from several areas of Mediterranean Sea, were analyzed. The sum of total DL-PCBs ranged from 0.22 to 6.33 ng g-1 (w.w.) for farm reared fish and from 0.04 to 12.96 ng g-1 (w.w.) for wild fish.
2007
Atti del 121st AOAC International Annual Meeting and Exposition
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/1780455
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact