The application of an electrochemical (impedance) tool for monitoring Escherichia coli contamination in shellfish was evaluated after 13 months of observation. The primary aim of the present study was to compare the standard most probable number (MPN) and mu-trac 4200 (log imped/100 g) for the assessment of E. coli contamination (log MPN/100 g) in non-depurated bivalve mollusks (BM) from five sampling areas of the Veneto-Emilian coast (Italy) (118 samples). The secondary aim was to evaluate the correlation between E. coli concentrations in BM and environmental factors on a large data set (690). The methods showed a moderate, positive correlation (0.60 and 0.69 Pearson and Spearman coefficients, respectively; P<0.01) in Ruditapes philippinarum. The McNemar test indicated analogous sample classification between methods, and the impedance method overestimated the most contaminated class (P=0.03; > 4,600 MPN/100 g). The results highlighted the suitability of the impedance method for a faster evaluation and routine use especially in clams, while in Mytilus it seemed less effective. Different models built by multivariate permutational variance analysis and multinomial logistic regression selected the suitable environmental features able to predict the E. coli load. Overall, salinity and season affected the E. coli contamination, whereas locally it was mainly influenced by hydrometry and salinity. The application of the impedance method coupled with environmental data analysis could help purification phase management to adhere to legal limits and could represent an advantage for local control authorities to define actions, considering extreme meteorological events' effects as a proactive reaction to climate change.
Evaluating Escherichia coli contamination in bivalve mollusks using the impedance method: a comparison with most probable number analyses and correlation with environmental parameters
	
	
	
		
		
		
		
		
	
	
	
	
	
	
	
	
		
		
		
		
		
			
			
			
		
		
		
		
			
			
				
				
					
					
					
					
						
							
						
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
			
			
				
				
					
					
					
					
						
							
						
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
			
			
				
				
					
					
					
					
						
							
						
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
			
			
				
				
					
					
					
					
						
						
							
							
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
			
			
				
				
					
					
					
					
						
						
							
							
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
			
			
				
				
					
					
					
					
						
							
						
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
			
			
				
				
					
					
					
					
						
							
						
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
			
			
				
				
					
					
					
					
						
							
						
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
		
		
		
	
Currò S.;Fasolato L.;Balzan S.
;Bargelloni L.;Cardazzo B.;Novelli E.
	
		
		
	
			2023
Abstract
The application of an electrochemical (impedance) tool for monitoring Escherichia coli contamination in shellfish was evaluated after 13 months of observation. The primary aim of the present study was to compare the standard most probable number (MPN) and mu-trac 4200 (log imped/100 g) for the assessment of E. coli contamination (log MPN/100 g) in non-depurated bivalve mollusks (BM) from five sampling areas of the Veneto-Emilian coast (Italy) (118 samples). The secondary aim was to evaluate the correlation between E. coli concentrations in BM and environmental factors on a large data set (690). The methods showed a moderate, positive correlation (0.60 and 0.69 Pearson and Spearman coefficients, respectively; P<0.01) in Ruditapes philippinarum. The McNemar test indicated analogous sample classification between methods, and the impedance method overestimated the most contaminated class (P=0.03; > 4,600 MPN/100 g). The results highlighted the suitability of the impedance method for a faster evaluation and routine use especially in clams, while in Mytilus it seemed less effective. Different models built by multivariate permutational variance analysis and multinomial logistic regression selected the suitable environmental features able to predict the E. coli load. Overall, salinity and season affected the E. coli contamination, whereas locally it was mainly influenced by hydrometry and salinity. The application of the impedance method coupled with environmental data analysis could help purification phase management to adhere to legal limits and could represent an advantage for local control authorities to define actions, considering extreme meteorological events' effects as a proactive reaction to climate change.| File | Dimensione | Formato | |
|---|---|---|---|
| ijfs-12-2-11103.pdf accesso aperto 
											Tipologia:
											Published (Publisher's Version of Record)
										 
											Licenza:
											
											
												Creative commons
												
												
													
													
													
												
												
											
										 
										Dimensione
										711.25 kB
									 
										Formato
										Adobe PDF
									 | 711.25 kB | Adobe PDF | Visualizza/Apri | 
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.




